[no] tacacs-server primary-host [data-port|mgta|mgtb]
Defines the primary interface port to use to send TACACS+ server requests.
Command mode: Global configuration
[no] tacacs-server secondary-host [data-port|mgta|mgtb]
Defines the secondary interface port to use to send TACACS+ server requests.
Command mode: Global configuration
[default] tacacs-server port <TCP port number>
Enter the number of the TCP port to be configured, between 1 and 65000. The default is 49.
Command mode: Global configuration
tacacs-server retransmit <1-3>
Sets the number of failed authentication requests before switching to a different TACACS+
server. The default is 3 requests.
Command mode: Global configuration
tacacs-server attempts <1-10>
Sets the number of failed login attempts before disconnecting the user. The default is 2
attempts.
Command mode: Global configuration
tacacs-server timeout <4-15>
Sets the amount of time, in seconds, before a TACACS+ server authentication attempt is
considered to have failed. The default is 5 seconds.
Command mode: Global configuration
[no] tacacs-server user-mapping {<0-15>
user|oper|admin}
Maps a TACACS+ authorization level to a switch user level. Enter a TACACS+ authorization
level (0-15), followed by the corresponding switch user level.
Command mode: Global configuration
Table 110 TACACS+ Server Commands