User`s manual
Cerebus® User’s Manual
Revision 13.00 / LB-0028 Page 46
2.x Interface
Use this window to record data. Some of the controls are similar to the TOC Interface. There are some additional
controls that are described below.
Figure 40 - File Storage - 2.x Interface
o File Options allows the user to enable or disable recording of a certain frequency data.
o File Name and Path: Click on Browse to choose a folder to record in and name the data file.
o Auto-Increment: If checked, it enables automatically incrementing the data filename every time recording is stopped.
For example, if the data file is named SampleData then the first file will be recorded as SampleData001, the next
SampleData002, etc.
o File Spec: Choose between the different file specifications. Refer to the File Format for information of the different file
specs.