Specifications

IN
OUT
Symbol which indicates the flow of
compressed air
or
Caution
1. About the mounting orientation of the products
Make sure to install this product on horizontal piping. If it is in-
stalled diagonally, laterally, or upside down, the drain separa-
ted by the element will splash to the outlet side.
Mounting
Selection
Caution
1. About the system composition of purifying com-
pressed air
Compressed air generally contains particulate contaminants
as listed below, though there are some variations due to the
compressor type and specifications. Determine the system
configuration according to the desired cleanliness of com-
pressed air and application, while referring to the “Air Prepara-
tion Equipment Selection Guide” for the AM series (Best
Pneumatics).
[Particulate contaminants in compressed air]
• Water (drainage)
• Dust sucked from ambient air
• Degenerated oil from compressor
• Solid foreign matter such as rust inside piping and oil
2. Select according to the maximum flow consump-
tion.
When compressed air is used for air blow, etc., find the maxi-
mum air consumption before selecting the size of the AM
series. (If compressed air exceeding the maximum flow rate is
supplied, it can result in decline of the cleanliness of com-
pressed air or element damage.)
Caution
Piping
In the case of the AFF75A to 220A, AMD801, 901, 800, 900,
1000
INLET and OUTLET of compressed air is labeled on the side
of flange. Be sure to connect correctly.
2. Use an air blower to flush the piping before con-
necting the piping.
Use an air blower to thoroughly flush the piping, or wash the
piping to remove any cutting chips, cutting oil, or debris from
inside the piping before connecting them.
3. Wrapping of sealant tape
When screwing in the pipes or fittings, make sure to prevent
cutting chips or the sealant material on the threaded portion of
the pipe from entering the piping. If sealant tape is to be used,
leave about 1.5 to 2 ridges of threads uncovered.
4. Modular connection
Mount the attached bracket on one side when connecting 2
sets. Mount the attached brackets on both sides when con-
necting 3 sets or more. As a guideline for the number of
brackets, one bracket should be mounted for every 2 prod-
ucts.
1. Connect it with IN and OUT ports in proper location.
It does not work with the connection reversed.
In the case of the AFF2C to 22C, 37B, 75B, AM150C to
550C, 650, 850
Verify the direction of the flow of the compressed air and the
” or “ ” mark that indicates the inlet of the product before
connecting. It cannot be used if connected in the opposite di-
rection.
Series AM
/AFF
Specific Product Precautions 2
Be sure to read this before handling. Refer to back pages 1 and 2 for Safety Instructions,
and “Precautions for Handling Pneumatic Devices” (M-03-E3A) for Common Precautions.