Instruction manual
Installing Optional Blackmagic Fiber Optic SFP
70
Installing the optional Blackmagic Fiber Optic SFP in your
Teranex Express Processor
WARNING
Precautions should be taken to reduce the risk of electrostatic discharge while installing the SFP module.
Installing or removing the Module
The Blackmagic Design Fiber Optic SFP module has a clasp to assist you in removing or installing the
module. The module is “hot-pluggable,” meaning that it may be installed or removed without powering
down the Teranex Express.
The Blackmagic Design SFP supports single mode optical fiber cable. It is bi-directional, supporting
video formats up to Ultra HD at 6Gb/s.
To install the Blackmagic Design SFP Module:
Step 1. Close the clasp before inserting the SFP module.
Step 2. Remove the cage cover from the optical module cage on the rear of the Teranex Express.
Step 3. Line up the SFP module with the optical module cage and slide it into the cage. Verify that the
SFP module is completely seated and secured in the cage by firmly pushing on the SFP module.
Step 4. If a dust protector is present on the SFP module, leave it in place until you are ready to install
your fiber optic cables.
To remove the Blackmagic Design SFP Module:
Step 1. Disconnect all fiber optic cables from the SFP.
Step 2. Open the clasp on the SFP module with your index finger or a small, flat-blade screwdriver.
Step 3. Grasp the SFP module and carefully remove it from the cage.
Step 4. Immediately place the SFP module in a static shielding bag.
Step 5. Insert an SFP module cage cover into the optical module cage of the Teranex Express when
no SFP module is installed.
Blackmagic Design SFP Module
Installing the SFP Module into the Teranex Express.
Installing Optional Blackmagic Fiber Optic SFP
OPTICAL
6G-SDI
REF IN
CAUTION!
RISK OF ELECTRIC
SHOCK - DO NOT OPEN
100-240V 1.7A 50-60Hz Fuze T5AL
USE ONLY 250V FUSES
IN A
IN B
LOOP A
LOOP B
OUT A
OUT B
OUT/IN
OPTICAL
6G-SDI
REF IN
CAUTION!
RISK OF ELECTRIC
SHOCK - DO NOT OPEN
100-240V 1.7A 50-60Hz Fuze T5AL
USE ONLY 250V FUSES
IN A
IN B
LOOP A
LOOP B
OUT A
OUT B
OUT/IN