Instruction manual
Teranex Processor Settings
33
Jam Sync The Jam Sync mode is similar to the Generate mode. However, when you press the
“Start” button, Jam Sync mode allows you to hold the output timecode generator
until a pre-determined timecode point is reached in your input video, called the
Jam Sync value. The Jam Sync value must be entered via the Set Timecode menu.
Set Timecode
The Set Timecode menu options you will have are determined by the selection you
make in the Start Source menu.
Start Source = “Input”
If the Start Source menu is set to “Input,” the Set Timecode menu will show “Input”
as the Start Value for the timecode generator. When you press the “Start” button,
the generator will start looking for a timecode match to the Jam Sync value you
have entered. When the match occurs, the generator will use that “Input” timecode
as the start value to generate free running output timecode.
Start Source = “Start Value”
If the Start Source menu is set to “Start Value,” the Set Timecode menu will display
an eight-character register that allows the entry of a specific starting value for the
generator. When you press the “Start” button the generator will look for a timecode
match to the Jam Sync value you have entered. When the match occurs, the generator
will use the start value you entered to generate free running output timecode.
Jam Sync
00:00:00:00
Start Value
Input
Timecode
Start
Start
Source
NextPrev
Setup
Timecode
Generator
Set
Timecode
Jam Sync>Set Timecode
Jam Sync
Generate
Input Regen
Input
Off
Timecode
Start
Start
Source
NextPrev
Setup
Timecode
Generator
Set
Timecode
Timecode Menu>Jam Sync