Instruction manual
Using HyperDeck
24
Command Reply No Remote Notes
7 - Sense Reply
0x78 0x00 Timer1Data - -
Current Time and
00:00:00:00
0x78 0x04 LTCUserBitsTimeData - -
Current Time and
00:00:00:00
0x78 0x06 VITCUserBitsTimeData - -
Current Time and
00:00:00:00
0x74 0x06 VITCTimeData - - Current Time
0x74 0x07 UserBitsVITCTimeData - - 00:00:00:00
0x74 0x08 GenTCData - - Current Time
0x78 0x08 GenTCUBData - -
Current Time and
00:00:00:00
0x74 0x09 GenUBData - - 00:00:00:00
0x74 0x10 InData - -
0x74 0x11 OutData - -
0x74 0x12 AInData - -
0x74 0x13 AOutData - -
0x74 0x14 CorrectedLTCTimeData - - Current Time
0x70 0x20 StatusData - -
Please see “Status Bits”
sheet: Limited to 9 bytes
of status, silently truncated
0x71 0x2E SpeedData - -
0x74 0x31 PrerollTimeData - -
0x71 0x36 TimerModeData - - Returns 0 (TimeCode)
0x72 0x3E RecordInhibitStatus - -
Supported RS-422 Commands