User Manual

Table Of Contents
Controls Tab
The Controls tab includes two menus. The Operation menu is used to select the type of field
conversion performed. The Process Mode menu is used to select the field’s format for the
output image.
Operation Menu
Do Nothing: This causes the images to be affected by the Process Mode selection
exclusively.
Strip Field 2: This removes field 2 from the input image stream, which shortens the
image to half of the original height.
Strip Field 1: This removes field 1 from the input image stream, which shortens the
image to half of the original height.
Strip Field 2 and Interpolate: This removes field 2 from the input image stream and
inserts a field interpolated from field 1, so that image height is maintained. Should be
supplied with frames, not fields.
Strip Field 1 and Interpolate: This removes field 1 from the input image stream and
inserts a field interpolated from field 2 so that image height is maintained. Should be
supplied with frames, not fields.
Interlace: This combines fields from the input image stream(s). If supplied with one
image stream, each pair of frames are combined to form half of the number of double-
height frames. If supplied with two image streams, single frames from each stream are
combined to form double-height images.
De-Interlace: This separates fields from one input image stream. This will produce
double the amount of half-height frames.
Reverse Field Dominance
When selected, the Field Order or Dominance of the image will be swapped.
Chapter – 100 Miscellaneous Nodes 2220