Test Sheet - BD

BEST TEST SERVICE SHENZHEN CO.,LTD Page 1 Of 16
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME:
SPEC.:
MFR.: Blackjack Lighting
TYPE:STL-06P-BL or PC-BD
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
Shielding Angle:
Test:U:120.00V I:0.0893A P:10.388W PF:0.9686 Freq:60.00Hz Lamp Flux:387.237x1 lm
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,46.8
UNIT:cd
C90/270,55.1
AVERAGE BEAM ANGLE(50%):50.9 DEG
0
70
140
210
280
350
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
PLANAR ISOLUX DIAGRAM(UNIT:lx)
MH=1m
S(m)
0
1
2
3
90
80
70
60
50
40
30
20
10
0
C(DEG)
180
160
140
110
91.0
68.0
23.0
11.0
6.80
2.30
DATA OF LAMP PHOTOMETRIC DATA Eff: 37.28 lm/W
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
CIE CLASS
up(%)
down(%)
S/MH(C0/180)
S/MH(C90/270)
UP,DN(C0-180)
UP,DN(C180-360)
CIBSE SHR NOM
CIBSE SHR MAX
STL-06P-BL or PC-BD
10.5
120.0
387.237
1
120.0
362.7
100.0
387.24
SEMI-D.
16.6
83.4
0.07
0.07
8.4,41.4
8.1,42.0
0.00
1.00
C Range: 0 - 360DEG
C Interval: 22.5DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.366
Temperature:25.6DEG Humidity:67.1%
Test Distance:2.457m [K=1.0000]Operators:David
Test Date:20 June 2018 Remarks: