Test Sheet - BD
BEST TEST SERVICE SHENZHEN CO.,LTD Page 7 Of 16
UTILIZATION FACTORS TABLE
NAME:
SPEC.:
MFR.: Blackjack Lighting
TYPE:STL-06P-BL or PC-BD
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
Shielding Angle:
Test:U:120.00V I:0.0893A P:10.388W PF:0.9686 Freq:60.00Hz Lamp Flux:387.237x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 54 43 36 53 43 36 51 42 36 29
0.80 63 52 44 62 51 44 59 49 43 36
1.00 70 59 51 69 58 51 65 58 50 42
1.25 77 66 58 75 64 57 71 62 56 47
1.50 82 71 63 79 69 62 74 66 60 50
2.00 88 78 71 85 76 70 80 73 67 56
2.50 92 83 76 89 81 75 83 76 71 59
3.00 96 87 81 92 85 79 86 80 75 62
4.00 100 93 87 96 90 85 89 84 80 66
5.00 102 96 91 98 93 89 91 87 83 69
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEG
C Interval: 22.5DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.366
Temperature:25.6DEG Humidity:67.1%
Test Distance:2.457m [K=1.0000]Operators:David
Test Date:20 June 2018 Remarks: