Test Sheet
BEST TEST SERVICE SHENZHEN CO.,LTD Page 7 Of 16
UTILIZATION FACTORS TABLE
NAME:
SPEC.:
MFR.: Blackjack Lighting
TYPE:HAL-21F-SN
DIM.:
SUR.:0.27*0.27*3.14
WEIGHT:
SERIAL No.:
Shielding Angle:
Test:U:120.00V I:0.2360A P:28.270W PF:0.9977 Freq:60.00Hz Lamp Flux:1772.01x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 53 41 34 53 41 34 51 40 34 27
0.80 63 51 43 62 50 43 60 49 42 35
1.00 71 59 51 70 58 51 67 60 50 42
1.25 78 67 59 77 66 58 73 64 57 49
1.50 83 72 64 81 71 64 78 69 62 54
2.00 90 81 73 88 79 72 84 77 71 62
2.50 95 86 79 92 84 78 88 81 76 66
3.00 98 90 84 96 89 83 91 85 80 70
4.00 103 96 91 100 94 89 95 90 86 75
5.00 106 100 95 103 98 93 98 93 90 79
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEG
C Interval: 22.5DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.366
Temperature:25.6DEG Humidity:67.1%
Test Distance:2.455m [K=1.0000]Operators:David
Test Date:04 June 2018 Remarks: