Test Sheet
BEST TEST SERVICE SHENZHEN CO.,LTD Page 7 Of 16
UTILIZATION FACTORS TABLE
NAME:
SPEC.:
MFR.: Blackjack Lighting
TYPE:HAL-11F-SN
DIM.:
SUR.:0.145*0.145*3.14
WEIGHT:
SERIAL No.:
Shielding Angle:
Test:U:120.00V I:0.1306A P:15.514W PF:0.9897 Freq:60.00Hz Lamp Flux:943.524x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 54 42 35 53 42 35 52 41 34 28
0.80 64 51 44 62 51 43 60 50 43 35
1.00 72 60 52 70 59 52 68 60 51 43
1.25 79 68 60 77 67 59 74 65 58 50
1.50 84 73 66 82 72 65 78 70 64 55
2.00 91 82 74 89 80 74 85 77 72 63
2.50 95 87 80 93 85 79 88 82 77 67
3.00 99 91 85 96 89 84 92 86 81 71
4.00 103 97 92 101 95 90 95 91 87 76
5.00 106 101 96 103 98 94 98 94 90 80
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEG
C Interval: 22.5DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.366
Temperature:25.6DEG Humidity:67.1%
Test Distance:2.455m [K=1.0000]Operators:David
Test Date:04 June 2018 Remarks: