Installation Sheet

BJL 150801
ASSEMBLY & INSTALLATION INSTRUCTIONS for GRD-11F-940
CAUTION: READ ALL INSTRUCTIONS CAREFULLY FOR SAFE OPERATION AND
INSTALLATION
CAUTION
1. Turn off the main power at the circuit breaker before installing the
fixture in order to prevent possible shock.
GENERAL
1. All electrical connections must be in accordance with local and national
electrical code (N.E.C) standards. If you are unfamiliar with proper electrical
wiring connections obtain the services of a qualified electrician. Remove the
fixture and the mounting package from the box and make sure
that no parts are missing by referencing the illustrations on the installation
instruction.
2. Dimming controller type: TRIAC phase control dimmer.
3. Recommended TRIAC dimmers: LEVITON: ILLUMATECH IPL06, SURESLIDE 6674
LUTRON: ARIADNI AYCL-153P, DIVA DVCL-153P, SKYLARK CTCL-153P, SKYLARK
SCL-153P
ASSEMBLY AND INSTALLATION
1. Take the fixture out of the box.
2. Take the back panel10away the fixture body12by loosing two
thumbscrews11.
3. Pull the supply wires (2&8) and the house ground wire (5) out of the outlet
box (1).
4. Make the wiring connections: connect the white supply wire (2) to the
white fixture wire (4); connect the black supply wire (8) to the black fixture
wire (7); connect the house ground wire (5) to the fixture ground wire (6)
using wire connectors (3).
5. Carefully tuck all wires back into the outlet box (1) and locate the back panel
10over the outlet box (1). Put the mounting screws (9) through the slots on
the back panel and then secure the mounting screws into the outlet box
tightly.
6. Install the fixture body into the back panel10by fastening 2 thumbscrews
11.
INSTALLATION IS NOW COMPLETED
BLACKJACK LIGHTING 1553 Barclay Blvd. ,Buffalo Grove, IL 60089
blackjacklighting.com Tel: 847-941-0588

Summary of content (1 pages)