Test Sheet
BEST TEST SERVICE SHENZHEN CO.,LTD Page 6 Of 14
UTILIZATION FACTORS TABLE
NAME: Cirque 18"pendant,Satin Nickel
SPEC.:
MFR.: Blackjack Lighting
TYPE:CRQ-18P-SN
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.0V I:0.2464A P:29.42W PF:0.9950 Lamp Flux:1329.86x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 33 20 12 32 19 12 29 18 11 4
0.80 42 27 18 39 26 17 35 23 16 6
1.00 49 33 24 46 32 23 40 30 20 9
1.25 56 40 30 52 38 28 45 33 25 12
1.50 61 46 35 57 43 33 49 38 30 15
2.00 69 55 44 64 51 42 55 45 37 19
2.50 74 61 51 69 57 48 59 49 42 22
3.00 79 67 57 73 62 53 62 53 46 25
4.00 84 74 65 78 69 61 66 59 53 30
5.00 88 79 71 82 73 66 69 63 57 33
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEG
C Interval: 22.5DEG
Range: 0 - 180DEG
Interval: 1.0DEG
Test Speed: HIGH Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.287
Temperature:25.6DEG Humidity:67.1%
Test Distance:2.802m [K=1.0000]Operators:David
Test Date:2018-01-03 Remarks: