Service manual

SKYJACK, Page 10 SJIII Compact Series
143909
Section 4 - Troubleshooting Information Service and Maintenance
Electrical System (Continued)
7. Proportional relay 21ACR defective.
Check relay, replace if defective. -
8. Loose or broken wire #2 from proportional relay 21ACR to base terminal block.
Check continuity. Replace if defective. -
9. Proportional controller S7 out of adjustment.
Adjust controller. Refer to Section 5, Joystick Adjusting Procedure. -
4.1-22 Forward Drive Function Inoperative
1. Loose or broken wire #16 from lift/drive switch S3 to base terminal block.
Check continuity. Replace if defective. -
2. Loose or broken wire #16 from base terminal block to forward drive valve coil 4H-16.
Check continuity. Replace if defective. -
3. Forward drive valve coil 4H-16 defective.
Check continuity through coil. Replace if defective. -
4. Loose or broken wire #02 from forward drive valve coil 4H-16 to base terminal block.
Check continuity. Replace if defective. -
5. Open diode D16.
Check diode. Replace if defective. -
4.1-23 Reverse Drive Function Inoperative
1. Loose or broken wire #15 from lift/drive switch S3 to base terminal block.
Check continuity. Replace if defective. -
2. Loose or broken wire #15 from base terminal block to reverse drive valve coil 4H-15.
Check continuity. Replace if defective. -
3. Reverse drive valve coil 4H-15 defective.
Check continuity through coil. Replace if defective. -
4. Loose or broken wire #02 from reverse drive valve coil 4H-15 to base terminal block.
Check continuity. Replace if defective. -
5. Open diode D15.
Check diode. Replace if defective. -
4.1-24 Brake will not Release
1. Diode D-16 forward or D-15 reverse is shorted or open.
Check diode. Replace if defective. -
2. Loose or broken wire #17 from base terminal strip to brake coil 3H-17.
Check continuity. Replace if defective. -
3. Brake valve coil 3H-17 defective.
Check continuity through coil. Replace if defective. -
4. Loose or broken wire #02 from brake valve coil 3H-17 to base terminal block.
Check continuity. Replace if defective. -
4.1-25 Two or more Functions at one time
1. Shorted diode.
Check continuity of all diodes. Replace if defective. -