Service manual

SKYJACK, Page 28 SJIII Series
Section 1 - Scheduled MaintenanceFunction Tests
1.2-3 Platform Control Console
1. Ensure base
emergency stop button is
pulled out.
2. Select off/platform/base key switch to
platform position.
3. Ensure main power disconnect switch is in on
position.
wARNiNG
Ensure that you maintain three points of
contact when using the ladder to mount/
dismount platform.
4. Use the ladder of aerial platform to access
platform.
5. Close the gate.
6. On platform control console, pull out
”emergency stop button.
Test Platform Emergency Stop•
1. Push in
emergency stop button
and attempt to activate any platform
function.
Result: All selected platform functions
should not operate.
Test Enable Trigger Switch•
1. Without activating
enable trigger
switch, attempt to activate any platform
function.
Result: All platform functions should not
operate.
Test Steering•
NOTE
Inclined drive (low speed/high torque) is
not available on 3215 and 3219 models.
1. Select lift/inclined drive/level drive switch
to either “
” inclined drive (low speed/
high torque) or
level drive (high
speed/low torque) position.
2. Activate and hold
enable trigger
switch.
3. Press rocker switch on top of controller
handle to left and
right.
Result: Steer wheels should turn left and
right.
Lift/Drive/Steer Enable
Trigger Switch
Rocker Switch
Horn Pushbutton
Lift/Inclined Drive/Level Drive
Switch
Emergency Stop Button/
Operation Light
Controller