Service manual
SKYJACK, Page 13SJIII Series
Section 5 - Procedures Service and Maintenance
5.3-3 LED Error Codes - Code Breakdown Chart
Diagnostic sequence dependant on LED flash code:
No Last Caldate 63
Load Not Calibrated 62
Height Not Calibration 61
An EZcal is required!
Waiting For Neutral 55
Drive/Lift Inputs Faulty! 56
Up/Down Select Inputs Active Together 54
EMS Inputs Faulty! 52
Check inputs on P2 pins 1,2,3,4,5,6,7,8.
P3-4 Short To Supply! 42
P3-4 Short To Supply? 44
P3-6 Short To Supply? 46
Disconnect plug P3. If fault clears there is a problem with the wiring from P3-4 or P3-6 to the rest of the vehicle.
Armguard Active! 23
Elevation Switch Shifted? 21
Elevation Switch Stuck? 22
If the 23 flash code is triggered by armguard, it will occur once then clean. This is not a true fault but just an indica-
tion of the reason for the vehicle stop. If the 21 or 22 flash code is triggered by a fault with the elevation switch, it
will not clear. Check that the elevation switch correctly opens/closes when the platform is raised/lowered.
P3-4 Short To 0V? 43
P3-6 Short To 0V? 45
Disconnect plug P3. If fault clears there is a wiring fault from P3-4 or P3-6 to the rest of the vehicle.
Invalid Load - Check Sensors 45
Check the voltage out of the pressure transducer, into P4-2. It should be between 0.5V (zero pressure) and 4.5V
(maximum pressure) and should vary as the platform load & position varies.
Waiting For B+ on P2-12 52
B+ Supply Too Low 51
P4-1 Or P5-1 Short To 0V? 41
Check that the battery voltage is not too low.
Verify battery voltage on P2-12.
Disconnect plug P4 – if the fault clears there is a wiring fault from P4-1 to the rest of the vehicle.