Installation guide
3
www.digiop.com
© 2011 Digiop, Inc. All rights reserved.
5. In the IP Setup window:
a. Select the Static option if it is not selected.
b. Enter the new IP address for your encoder into the IP Address eld.
c. Enter the subnet mask of your computer into the Subnet Mask eld.
d. Enter the gateway of your computer into the Gateway eld.
e. Click SETUP. A Login window will open.
6. In the Login window, enter the ID and PW
(password) for your encoder and click Login. The
default administrator values for the ID and PW are
root and pass.
7. In the IPAdmin Tool window, click Refresh. Verify that the entry representing the encoder now
shows the new IP address.
Step 5. Setup encoder Basic Configuration
To view video images from the encoder, at a computer attached to the LAN where the encoder is installed,
open Microsoft
©
Internet Explorer and go to:
http://<IP address of the encoder>
In this example, the IP address is 192.168.1.201. Enter: http://192.168.1.201
If prompted to install ActiveX controls such as AxAll.cab (publisher Cap Co), AxPTZ, or AxNVC, follow screen
prompts to install the software.
NOTE
To load these ActiveX controls, you may need to adjust the security settings of your browser to
accept add-ins from unknown publishers.
SETUP Button
After logging into your encoder, if you cannot see live video from the encoder and the message: “Can not
Create XMLDOMDocument Install MSXML4.0” appears, download and install the MS XML 4.0 library. This
library can be found at:
http://www.microsoft.com/downloads/details.aspx?familyid=3144B72B-B4F2-46DA-B4B6-
C5D7485F2B42&displaylang=en
After the encoder view screen appears, click SETUP and enter the default User name and Password, root
and pass.
In the SETUP window, go to Basic Conguration > Users.
In the User list, click root to highlight it, and then click Modify. Enter a new password and click OK. In the
Users screen, click Apply, and then click OK to restart the server.
Go to Basic Conguration > Date & Time.
On the Date & Time screen, set the Time Zone, Method, and Time Synchronization options. Click Apply.
Go to Video & Audio > Video-in.
On the Video Input Setting screen, click the PREVIEW button to open a window showing the video stream
from the camera.
Adjust the Brightness, Contrast, Hue, Saturation, and Sharpness to perfect the video image. After changing
parameters, click Apply.
Click VIEW to exit SETUP mode and return to the web view screen.