User manual
17H.264 DVR User Manual
SECTION 3: SYSTEM SETUP
RTS-485 D+
RTS-485 D-
Open the PTZ submenu by selecting the submenu button.
NOTE
Connect speed dome cameras that support RS-485 directly to the RS-485 port. If the camera is controlled through an RS-232C
interface, use an RS-232C to RS-485 signal converter.
Use the PTZ setup screen to select the following options for the camera PTZ controller:
CHANNEL: Channel connected to a PTZ device
NAME: Protocol type
SPEED: 19200, 14400, 9600, 4800, 2400
ID: 0 ~ 63
3.4.4 MOTION ZONE Setup
Select MOTION ZONE using the p, q, t, and u buttons, select either PARTIAL ZONE or FULL ZONE, then press SEL.
FULL ZONE: The motion sensor is active on the whole screen. Set the level of sensitivity for MOTION SENSITIVITY.
PARTIAL ZONE: The motion sensor is active in the set detection frame (highlighted in green). To select or deselect a block
for motion detection, use the
p, q, t, and u buttons to move to the block, then press SEL. Press ESC to return to the
DEVICE menu.