SDS
Safety Data Sheet
Page 3 of 7
Black Flag Flying Insect Killer
3
Revision date: 12/14/2015
Personnel precautions: Remove all sources of ignition. Wear personnel protective
equipment as recommended in Section 8. Wash
thoroughly after handling.
For emergency responders: If specialized clothing is required to deal with the spillage,
take note of any information in Section 8 on suitable and
unsuitable materials.
Environmental precautions: Avoid dispersal of spilled material and runoff and contact
with soil, waterways, drains and sewers.
Methods for containment and
cleaning up: Stop leak if without risk. Move containers from spill area.
Before attempting clean up, refer to hazard data given
above. Small spills may be absorbed with earth, sand or
absorbent material swept up and placed in suitable,
covered, and labeled containers. Prevent large spills from
entering sewers or waterways. Contact emergency
services and supplier for advice. Never return spills in
original containers for re-use.
Precautions for safe handling: Put on appropriate personal protective equipment as
recommended in Section 8. Pressurized container: protect
from sunlight and do not expose to temperatures
exceeding 50°C (122°F). Do not pierce or burn, even after
use. Do not ingest. Avoid contact with skin, eyes and
clothing. Avoid breathing vapor or mist. Use only with
adequate ventilation. Store and use away from heat,
sparks, open flame or any other ignition source. Use
explosion-proof electrical equipment. Use only non-
sparking tools. Empty containers retain product residue
and can be hazardous.
Storage: Store in a cool, dry area away from open flame. Do not
store above 50°C (122°F).
Exposure guidelines:
Exposure Limits
OSHA PEL ACGIH TLV SupplierOEL
Chemical name
ppm mg/m
3
ppm mg/m
3
ppm mg/m
3
Pyrethrins TWA ------ 5 ------ 5 Not listed
Permethrin TWA None None None
Piperonyl butoxide TWA None None None
Petroleum distillates,
hydrotreated light
TWA Not listed ------ 200 Not listed
Isobutane TWA Not established 1000 ------ Not established
Propane TWA 1000 1800 1000 ------ Not established
Engineering controls:
General ventilation normally adequate.
Section 6 - Accidental Release Measures
Section 7 - Handling and Storage
Section 8 - Exposure Controls / Personal Protection