WARNING
This conversion kit
shall be installed by a
quali ed service agency
in accordance with the
manufacturer's instructions
and all applicable codes and
requirements of the authority
having jurisdiction.
If the information in these
instructions is not followed
exactly, a  re, explosion
or production of carbon
monoxide may result
causing property damage,
personal injury or loss of
life.
The quali ed service agency
is responsible for the proper
installation of this kit. The
installation is not proper and
complete until the operation
of the converted appliance is
checked as speci ed in the
manufacturer's instructions
supplied with the kit
.
If the unit is to be used on propane
convert as follows using the
components supplied with this
replace:
CAUTION
The gas supply and electrical power
shall be shut off before proceeding
with the conversion.
Note:
Factory supplied components must be used
to ensure correct input. After conversion
con rm proper manifold pressure.
1. Ensure the burner, pilot and gas
supply are turned off, and the
appliance has cooled.
2. Using a 1/2” wrench, undo the natural gas
burner ori ce, (marked #32). (Fig. #15)
3. Apply a small amount of pipe joint com-
pound to the threads of the propane
burner ori ce (marked #48) to ensure
a good seal, before screwing it into the
tting.
4. Open primary air shutter fully.
5. With a 7/16” wrench loosen the pilot head
on the pilot assembly (Fig. #16)
6. Slide the pilot adjustment band over and
ensure that the hole in the ori ce band is
showing. (Fig. #17 indicates NG position,
Fig. #18 indicates LP position)
7. Remove access panel, 10 screws, and
set aside. (Fig. #23)
Fig #15
Fig #16
Fig #17
Fig #18
Propane Conversion