Installation guide
Installing Power Supplies
BlackDiamond X8 Series Switches Hardware Installation Guide
55
To install a power supply:
1 Remove the power supply ventilation cover as follows:
a Loosen the retaining screws at the top corners of the cover panel.
b Pull outward on the retaining screws to tilt the cover panel away from the front of the chassis.
c Lift the cover panel away from the chassis.
Figure 22: Removing the Power Supply Ventilation Cover
2 Identify the power supply bay where you will install the power supply.
Power supply bays are numbered from 1A to 8B (Figure 23). To establish an N+N redundant power
configuration, install power supplies in both the upper and lower rows.
Figure 23: Power Supply Bay Numbering on the Chassis
3 On the front of the power supply, push the release button to unlatch the insertion/ejector lever.
BDX_017
BDX_031
1A
5B
2A
6B
3A
7B
4A
8B