Installation guide

BlackDiamond X8 Switch
BlackDiamond X8 Series Switches Hardware Installation Guide
111
Environmental Data
Operating conditions Operating temperature range: 0° C to 40° C (32° F to 104° F)
Operating humidity: 10% to 93% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g), 11 ms, 60 shocks
Operational sine vibration: 5 to 100 to 5 Hz @ 0.2 g, 0 to peak, 0.1 oct./min.
Operational random vibration: 3 to 500 Hz @ 1.5g rms
ASTM D3580 random vibration unpackaged 1.5g
NOTE: Operating temperature refers to the input air temperature in the
environment and applies to all switch components. The show temperature
CLI command displays the internal temperature of individual hardware
components, as well as the allowable internal temperature range for each
component.
Storage & transportation
conditions (packaged)
Transportation temperature: –40° C to 70° C (–40° F to 158° F)
Storage and transportation humidity: 10% to 93% relative humidity,
non-condensing
Packaged shock (half sine):
<50 kg 180 m/s
2
(10 g), 6 ms, 600 shocks, modules
>50 kg 100 m/s
2
(6 g), 11 ms, 600 shocks, chassis
Packaged random vibration:
5 to 20 Hz @ 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz
14 drops minimum on sides & corners
@ 39.5" <22 lb (10 kg) modules
@ 11.8" <110 lb (50 kg) chassis
Acoustic Sound
Sound pressure for comparison
to legacy standards
Low Speed: 60.3 dB(A) per ISO 7779:2010
Medium Speed: 66.0 dB(A) per ISO 7779:2010
High Speed: 82.3 dB(A) per ISO 7779:2010
Sound power in accordance with
EN 300 753 v1.3.1 (2011-11)
Low Speed: 72.0 dB(A) per ISO 3744:1994
Medium Speed: 78.0 dB(A) per ISO 3744:1994
High Speed: 94.4 dB(A) per ISO 3744:2010
Declared sound power in
accordance with EN 300 753
v1.3.1 (2011-11)
Low Speed: 7.5 B(A) in accordance with ISO 9296:1998
Medium Speed: 8.1 B(A) in accordance with ISO 9296:1998
High Speed: 9.7 B(A) in accordance with ISO 9296:1998
Table 12: BlackDiamond X8 Switch Technical Specifications (Continued)