Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.3.4 Release Notes
96
Resolved Issues in ExtremeXOS 12.3.3
The following issues were resolved in ExtremeXOS 12.3.3. The numbers shown in column one of the
following table are for internal reference and can be ignored. ExtremeXOS 12.3 includes all fixes up to
and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.4, and
ExtremeXOS 12.2.2-patch1-12. For information on those fixes, see the release notes for the specific
release.
Table 43: Platform-Specific and Feature PDs
PD Number Description
General
PD4-723134513,
PD4-717148757
netTools memory utilization increases if the switch is not able to resolve the server IP
address for SNTP
PD4-826713926,
PD4-539277416
Failsafe account authentication fails when trying to access a switch using SSH by way of
a management port.
PD4-698458401 Every 300 seconds, kill entries installed by PIM are not removed from hardware,
therefore, traffic for those entries does not hit the CPU.
PD4-888296253,
PD4-642569015
On BlackDiamond 10808 and 12800 series switches, when multiport FDB entries are
created, the CPU forwarded traffic is always sent to the lowest port.
PD4-852858158,
PD4-694359201
Process cliMaster dies with signal 6 in some cases.
PD4-855783054,
PD4-769156523
The message MSM-A: Error while saving "psePort": is displayed when a
save command is executed after reconfiguring a slot as a G48te2 (PoE) to G48te2
module.
PD4-843337963,
PD4-748079627
The debug log <Info:thttpd.info> 13 line feeds removed is not necessary
and is shown when configuring a switch with HTTPS.
PD4-750913401 When removing I/O modules from a chassis, the following warning is shown in the log:
<Warn:HAL.Sys.Warning> MSM-A: Sys-Health-Check LinkScan
Notification IO : slot 4 unit 0 port 10 link Down
BlackDiamond 8800 Series Switch
PD4-819677451 A HAL task failure may occur on the primary or backup MSM of a BlackDiamond 8800
series switch when the VRID value given in the debug hal show ipv4Mc vrId
<vrId> command is greater than 10.
PD4-882862398,
PD4-767856469
After running the save command and rebooting a switch with a VLAN translation
configuration, duplicate packets are sent to member VLANs from the translation VLAN.
PD4-860761298,
PD4-767590011
A devmgr process crash may occur when the show version command is executed.
PD4-843338016,
PD4-796910653
The switch stops forwarding traffic after disabling remote mirroring.
BlackDiamond 12800 Series Switch
PD4-732450009,
PD4-519335296
When hot-swapping an I/O module, a DiffServ configuration does not take affect.
PD4-900776871,
PD4-735984501
DUT crashes while configuring static routes via 6in4 tunnels.
PD4-856182526,
PD4-698686480
Even after a vMAN ethertype is changed using the CLI, packets are egressing out the
service vMAN using an older vMAN ethertype.