Specifications

ExtremeXOS 12.3.4 Release Notes
91
PD4-1344770191 Inserting a MSM-G8X module running ExtremeXOS 11.6.1 or earlier software as a
backup on a BlackDiamond 8806 chassis with 600/900 W AC PSUs causes the switch to
continuously reboot.
PD3-190363671,
PD4-1313038681
The following error message is displayed while hot swapping PSUs:
Unable to read PSU-2 FRU data. Try reinserting PSU more quickly.
Workaround: Remove and reinsert the PSU quickly. Insert the PSU in a single,
continuous motion with a firm push.
Note: This problem is fixed in PSU Controller firmware version 2.18. Run the install
firmware command to install the new firmware on the PSU Controller modules.
PD4-1206112163,
PD4-1203047506
On BlackDiamond 8800 series switches, the inline power state remains delivering on
the G48P and G48Pe modules after a powered device is removed from a port.
PD4-1191020319 When a 10M SFP+ passive copper cable is inserted into an 8900-10G24X-c module, it is
detected as a 1 Gbps optic instead of a 10 Gbps optic and the port is incorrectly
reconfigured for 1 Gbps operation. SFP+ passive copper cables of other lengths do not
experience this problem.
PD4-1217032401 When running pings for an L3 interface, ping packets are dropped when IP forwarding is
enabled on a BlackDiamond 8800 series switch.
PD4-1198241441 When configuring PIM Sparse mode on a BlackDiamond 8800 original series switch, a
memory leak is detected.
Workaround: Disable multicast route compression by running the configure
forwarding ipmc compression off command.
PD4-1147533386,
PD4-983957922
After running an MSM failover, the backup MSM shows an asterisk in the command
prompt after rebooting the switch. To clear this, save the configuration.
RT030101_TEST_LAB.2 >
* RT030101_TEST_LAB.2 > show slot
PD4-1047390381,
PD4-910971021
Port Summary Monitor timestamps display on a console as part of the show port
<port _list> command output.
PD4-964896284 When configuring PIM Sparse mode on a BlackDiamond 8800 series switch with c-series
I/O modules, a memory leak is detected.
Workaround: Disable multicast route compression by running the configure
forwarding ipmc compression off command.
PD4-975082490 EDP information is not displayed when a port is not a member of a VLAN or is tagged.
PD4-936088722,
PD4-791316018
When using SCP to download an image, the image fails to install on the backup MSM
and the following error is displayed:
Installing to MSM-BError: Failed to install image - tar: /
scratch/bd8800-12.1.3.14.xos: No such file or directory.
BlackDiamond 10800 Switch
PD4-1272649513,
PD4-804225168
ESMI related warning messages are seen in the output of the show log command
whenever an SSL certificate with a key length of 4,096 is created or the HTTPD process
is restarted.
PD4-1035637713 Fans on a BlackDiamond 10800 switch may run at a higher RPM, causing unacceptable
noise levels.
BlackDiamond 12800 Series Switch
PD4-1217032476,
PD4-1185696661
A BGP process crash with signal 11 occurs when disabling and enabling a BGP peer
with 15,000 routes.
PD4-1243529054,
PD4-320452728
Running CLI commands on a BlackDiamond 12800 series switch with an MSM-6R
module shows an intermittent delay of 30 to 60 seconds during command execution.
Table 42: Platform-Specific and Feature PDs
PD Number Description