Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.3.4 Release Notes
90
PD4-977234454 Configuring UPM profiles to include the show port info detail command results in
the show profile history command output showing the status as failed.
PD4-1028753771 The process "exsshd" crashes with a signal 11 error when closing a session window
without using the proper logout.
PD4-1087700857,
PD4-698458422
PIM DM causes higher bandwidth consumption with multicast when no subscribers exist.
PD4-1084010391,
PD4-901582203
The typographical error in the following error message has been corrected:
<Warn:AAA.RADIUS.serverSwitch> MSM-A: Switch to server...
PD4-1084205109,
PD4-1027500181
The show tech all detail logto file command does not complete execution.
PD4-980403527,
PD4-899333484
The thttpd process CPU utilization increases and HTTP/HTTPS is not accessible if sock/
stress attack is performed on an HTTPS port. This issue persists indefinitely even after a
sock/stress attack is removed.
PD4-975759347 When stacking redundancy and telnet access-profiles are configured, the following error
is displayed:
Connection refused
Connection closed by foreign host.
PD4-968719352 When running the terminate process exsshd forceful command while an SSH
session is in progress, the SSH session does not shut down even if it is no longer seen
in the output of the show session command. When restarting the SSH session using
the start process exsshd command, the switch appears to hang while waiting for
the ongoing SSH session to be terminated.
PD4-929585833,
PD4-507170288
Traffic received on an STP/EAPS blocked port is being sent to the CPU if the source
MAC address of the incoming packet matches the MAC address of the DUT system.
PD4-963068135 An ExtremeXOS switch reboots with memory depletion for a 128 memory block while
loading a flow-redirect configuration.
PD4-955373111,
PD4-920567275
Process FDB may die with signal 11 when processing SNMP Get requests for
dot1dTpFdbTable.
PD4-995543551 When configuring IP MTU as 9,216, the value is reduced to 9,194 after upgrading to
ExtremeXOS 12.1 or later.
PD4-962772344,
PD4-924242747
The FDB process may die with signal 11 when the show fdb statistics command
is executed.
PD4-974227435,
PD4-767595507
The log filter is not shown in the output of the show upm profile <profile-name>
command.
PD4-983772991 The ifMauDefaultType MIB is populated with the wrong value when a switch is running
ExtremeXOS 12.3.3 software.
PD4-944885511 Receiving LACP PDUs that are larger than 500 causes the LACP process to die with a
signal 11 error.
PD4-943063565 The cliMaster fails with a signal 6 error when running the show configuration pim
command while PIM is configured with a static CRP.
BlackDiamond 8800 Series Switch
PD4-1313038681,
PD3-190363671
The following error message is displayed while hot swapping PSUs:
Unable to read PSU-2 FRU data. Try reinserting PSU more quickly.
Workaround: Remove and reinsert the PSU quickly. Insert the PSU in a single,
continuous motion with a firm push.
Note: This problem is fixed in PSU Controller firmware version 2.18. Run the install
firmware command to install the new firmware on the PSU Controller modules.
Table 42: Platform-Specific and Feature PDs
PD Number Description