PD4-1227274291 In some cases, the output for the show port <port-list> qosmonitor command
shows the packet transmission for QP4 for the traffic that is redirected using ACL.
PD4-1230649571,
PD4-1221696686
ExtremeXOS software is unable to upgrade an ExtremeXOS software license to any
switch that has a serial number beginning with 0953x-xxxx using the enable license
file <license-file.xlic> command.
Workaround: Enable the license by running the enable license <key> command.
PD4-1171267551,
PD4-1101461860
The run msm-failover command causes the process exsh to crash with signal 6 if
any CLI commands are entered during a telnet session.
PD4-809832177 An ICMPv6 “Packet Too Big” message is not sent when discarding IPv6 packets larger
than the outgoing ip-mtu.
PD4-1038555578 netTools crashes with signal 11 when a continuous ping is configured for more than 10
SSH or telnet sessions.
PD4-1023079871 Disabling learning on a VLAN results in LACP packets being dropped.
PD4-1156762929 A triggered IGMP query with the wrong 802.1Q tag is sent on a vMAN enabled port.
PD4-1130790465 A switch reboots because a system crash occurs when software is transmitting control
packets on a VLAN while the VLAN is bei25ng deleted.
PD4-1193582811 Traffic ingressing a G48T, G48P, G24X, G8X, or 10G4X module that egresses a load
sharing member port on a different I/O module is dropped when an 8900-MSM128
module is in use. In the case of a stack that contains an original series Summit X450
and X650, traffic ingressing the Summit X450 that egresses a load sharing member port
on a Summit X650 switch is also dropped. Only certain LAG groups are affected, most
notably, the first LAG group is not affected.
PD4-1113787037,
PD4-1007713804
Disabling learning on a VLAN, or creating a remote mirroring VLAN, causes excessive
flooding.
PD4-1150707179,
PD4-931823732
A loop occurs after disabling learning on a protected VLAN on an EAPS master.
Workaround: To stop the loop, disable and enable the EAPS primary port.
PD4-1124774241,
PD4-1099203316
Egress vMAN ACLs are not getting matched, even though the traffic matching the ACL
match condition is egressing the switch port.
PD4-938840511 CPU utilization threshold cannot be cleared through SNMP.
Workaround: Run the disable cpu-monitoring command.
PD4-1111322167 When running the disable subvlan-proxy-arp vlan command on a subVLAN,
clients are not able to resolve the ARP request for the superVLANs interface IP address.
PD4-846924113 The CLI command configure ports continues to show the unsupported option all.
PD4-990080561 In CLI non-persistent mode, modifying a port in a VLAN from an untagged port to a
tagged port deletes the port from that VLAN.
PD4-1084010417,
PD4-901961135
When an SNTP client is configured, the following log message is displayed every 4,096
seconds:
Setting hwclock time to system time, and broadcasting time Tue
Aug 18 19:40:00 2009:
Setting hwclock time to system time, and broadcasting time Tue
Aug 18 20:48:16 2009:
Setting hwclock time to system time, and broadcasting time Tue
Aug 18 21:56:32 2009:
PD4-950113951,
PD4-740925847
The following error message is displayed in the log when adding ports to an ESRP slave
VLAN.
<Crit:vlan.err.criticalInfo> MSM-A: Critical Info:
sysctlWriteSetting: cannot open file.
PD4-1021905215,
PD4-1013258326
An FDB refresh fails on a port when there is active traffic and a link flap on another port