Specifications

ExtremeXOS 12.3.4 Release Notes
83
Known Behaviors
The following are limitations in ExtremeXOS system architecture that will not be resolved.
Table 39: Platform-Specific and Feature PDs
PD Number Description
General
PD4-757563008 After hot swapping an MM-A, the output for the show power budget command shows
the wrong power information.
PD4-730473090,
PD4-549927751
Running diagnostics on a slot and then running the debug hal show sys-health-
check command shows an incorrect bcmRX ? message.
BlackDiamond 8800 SeriesSwitch
PD4-1306132018 In the SNMP MIB, the values for ModuleconfiguredType and ModuleInsertedType for the
10G4Xc and 10G8Xc I/O modules are incorrect.
BlackDiamond 20808 Switch
PD4-1004307581 You cannot create more than 2,000 ACL rules with ACL actions meter and count.
PD4-841530197 The install firmware command displays a lot of errors in the log and the HAL CPU
goes to 99% capacity.
FE200 on XBAR 3 as the command EXTRUC_FE_WRITE_CMD Failed,
Reason: UCPIPE_ERROR
08/10/2009 02:58:43.26 MM-A: Error Register Write ExtremeFE200Writ
eUc Offset: a10 Value ffffffff for Fabric Slot: 3
08/10/2009 02:56:32.29 MM-A: Slot-8 FAILED (3) Error Generic
Error(-1) from HAL on CardExec POWER_OFF(10) for slot 8
08/10/2009 02:56:32.29 MM-A
PD4-932420175 A link does not come up on a BlackDiamond 20800 series switch when a mini-GBIC is
connected to a GBIC in a third-party switch.
Workaround: Run the configure port auto off speed 1000 duplex full
command to configure a BlackDiamond 20808 switch, or third-party switch, to turn off
autonegotiation and manually configure the speed as 1000 Mbps, and duplex full.
PD4-1004307843,
PD4-1004307581
A policy file with 1,000 meters and counters cannot be reconfigured after applying a
refresh policy.
# configure access-list irl1kmtrs port 8:35
Error: Operation is not completed due to unavailability of
counter resource
Configuration failed on backup MSM, command execution aborted!
# show access-list
No entry found!
PD4-842516648 Traffic is not distributed on LAG group ports when multiple ingress and egress MAC IP
addresses are used.
PD4-615185171 LEDs are not working on the XFM.
Workaround: Run the show fabric command to verify that all modules are in an
operational state. Hot swap any that are not in an operational state and rerun the show
fabric command.
PD4-669582350 MAC addresses are not learned in software on BlackDiamond 20808 switches with EAPS
configured even after 20 seconds. This does not impact system performance.
Workaround: Run the show fdb hardware <MAC> <vlan name> slot all
command to verify the FDB entries.