PD4-1205978779 Rebooting a BlackDiamond 20800 series switch after installing a new ExtremeXOS image
displays the following critical error messages:
BD-20808.5 # reboot
Are you sure you want to reboot the switch? (y/N) Yes
############################## CRITICAL ERROR
###############################
devmgr: dmps.c:563: power_add(): REASON: total->volt[i] == p2-
>volt[i]
##################################################################
############################## CRITICAL ERROR
###############################
devmgr: dmps.c:563: power_add(): REASON: total->volt[i] == p2-
>volt[i]
#######################################
PD4-927699591 Running an ExtremeXOS 12.3 image in the Delay Measurement Message (DMM)
originator, and a later version of ExtremeXOS on a BlackDiamond 20808 on the other
end, Y.1731 does not work. The Delay Measurement Reply (DMR) is received by the
originator, but rejected due to an incorrect check in the application.
PD4-865667843 PFC uC fails to turn off the power supply once it detects a failed power supply. The bad
power supply takes 2.5 minutes to boot up. The PFC uC reads the I/O PIN associated
with the PSU alarm PIN and fails the PSU, but it does not power down the bad PSU.
PD4-843054490 Fans go into a failed/empty state and I/O modules are powered off after upgrading
firmware on a BlackDiamond 20808 using the force option.
PD4-861903959 When the backup MM is not yet synced (because of run msm-failover or running
diagnostics) and one performs an MM-failover, the command is accepted, however, both
MMs will then reboot.
Workaround: Make sure that run-time diagnostics command shall check both MMs
are sync before running the diagnostics.
PD4-853995054 The process upgrade_fw crashes with signal 11 when downgrading a BlackDiamond
20808 switch.
PD4-861903871 After loading image ExtremeXOS 12.3.2.5 on a BlackDIamond 20808 switch, the show
log command output shows the following error:
<Erro:HAL.Sys.Error> MM-B: Unable to get odometer for power
supply 5
The same log error is displayed when a failover occurs on MM-A.
PD4-847978862 A monitor port does not come up after enabling a port after a DUT is rebooted with a
disabled monitor port. The following error is displayed while rebooting:
MM-A: voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
08/15/2009 16:47:02.47 < Erro:HAL.Card.Error > MM-A:
voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
PD4-851358292 During a firmware upgrade, the "watchdog expiration warnings" and "kernel thread stuck"
messages may appear on an MM console.
PD4-845017407 The following error is seen when running the install firmware command on a GM-40XB
module in a BlackDiamond 20808 switch:
<Erro:HAL.Card.PowerStateError> MM-A: A request to power down
slot 8 failed - returning a completion code of -1.
Table 38: Platform-Specific and Feature PDs (Continued)
PD Number Description