Specifications

ExtremeXOS 12.3.4 Release Notes
71
PD4-730221901 Refreshing an ACL on an MM-B while running an MSM failover on MM-A causes MSM-A
to lose the ACL configuration on MSM-A.
PD4-749215601 Running the install firmware command generates the following error message:
reading from file /dev/mtd0 failed: Cannot allocate memory
.FAILED: SLOT 18, MM PMON
UPGRADE NOT REQUIRED: SLOT 18, MM Spanky Primary
Error:can't read "pfc": no such variable
PD4-737811617 Creating a blackhole FDB entry on a BlackDiamond 12800 series switch still forwards
traffic from a BlackDiamond 20808 to a BlackDiamond 12800.
PD4-757707981 Proxy ARP does not work in a PVLAN.
PD4-552222911 DUT is hanging with a busy message (dots) after configuring 7,250 ingress dynamic
ACLs with conduit errors.
PD4-561358261 If you create a super VLAN and a sub-VLAN in different virtual routers you are able to
bind the VLANs. Super VLANs and sub-VLANs should belong to the same virtual router.
PD4-631700490 When PIM and PIM snooping are enabled on the same VLAN, and if that VLAN happens
to be a PIM egress VLAN, traffic forwarding does not happen on the VLAN.
PD4-690958111 After running the unconfigure switch all command, an I/O module may stick in
the booting state, resulting in the switch continually rebooting.
PD4-624062541 Jumbo frames are not mirrored to monitor ports on Summit X650-24t switches when
one-to-many mirroring is configured.
PD3-131866114 BlackDiamond 8800 series and Summit series switches do not support LPM hardware
forwarding using IPv6 routes with a mask length greater than 64 bits. As a result, IPv6
packets may be forwarded in hardware to a different next hop by using a route with a
mask length less or equal to 64. This occurs even though a route with a mask length
greater than 64 with the correct next hop is known in software, but not in hardware. The
following log message is logged when the first route with a mask length greater than 64
is added:
<Noti:HAL.IPv6FIB.Notice> MSM-A: vrId 2 dest 3218:: / 77 nexthop
: IPv6 routes w/ mask len > 64 not supported in HW. Packets may
be forwarded using less-specific routes.
PD4-491938681 A user cannot change the password for a local administrator account when logged in
using a RADIUS administrator account.
PD4-489592307 DUT is not sending an "icmp destination unreachable" message to the source when it
receives a jumbo packet with a "dont fragment" bit message. This applies to
BlackDiamond 10800 and BlackDiamond 20808 switches only.
PD4-489359602 Conflicting Link Fault Signal (LFS) alarms are shown when disabling local ports.
PD4-489142320 One Gigabit ports set to auto on flap twice during a switch reboot.
PD4-486972363 Bandwidth for the detour Label Switched Paths (LSPs) are calculated from the point of
local repair (PLR) node to the egress node, and not from the PLR node to the merge
point (MP). Therefore, detour LSP is signaled only when there is enough bandwidth that
is equal to or greater than the requested bandwidth for the detour LSP from the PLR
node to the egress node.
PD4-448603051 The unconfigure pim vlan command clears (unconfigures) an SSM configuration on
a VLAN but the VLAN continues to operate in the SSM VLAN, even after running the
disable pim and enable pim commands.
PD4-470597781 When a local VLAN with 32 subnet-mask IP addresses is down, the dynamic route with
the same 32 subnet-mask IP addresses is not reachable.
PD4-460892051 Installing different versions of an ExtremeXOS image and an SSH image displays the
following error message:
Failed to install image- cannot read spec file" in the log
"upgrade failed installation:got error from installer DLL"
Table 38: Platform-Specific and Feature PDs (Continued)
PD Number Description