Specifications
ExtremeXOS 12.3.4 Release Notes
105
PD4-732017639,
PD4-576392401
The upload debug command returns the error Error: tftp: The: Unknown host
and the upload fails if the SNMP sysname contains spaces.
PD4-726580975,
PD4-498613775
A HAL crash with signal 11 error occurs on stacking platforms after running diagnostics on
one of the stacking nodes.
PD4-731919002,
PD4-623659203
The xml-mode process dies with signal 11 when an “execConfig” XML API request is
received.
PD4-734167511,
PD4-422347775
Interrupting the ping command initiated from an ExtremeXOS switch by pressing CTRL+C
may cause a “cliMaster” process to crash with signal 11 when a user exits that CLI session.
PD4-469889565,
PD4-274249122
If a Summit switch populated with an XGM2-2bt module is rebooted, a false link up is seen
on 10G links connected to the XGM2-2bt ports approximately 30 to 50 seconds before the
switch has fully booted.
PD4-313453484 A 1 Gigabit port link flaps twice when configuring auto off speed 1000 duplex
full. This does not occur when configuring auto on.
BlackDiamond 8800 Series Switch
PD4-751617335 On a BlackDiamond 8810, when pulling out the backup MSM-A, the master MSM-B could
not forward EAPS controlling messages (Hello PDU).
PD4-720590791 Traffic does not resume forwarding after disabling and enabling a VLAN or port on a
BlackDiamond 8900 series module G96T-c on some slots.
BlackDiamond 10808 Switch
PD3-14127903,
PD3-13538171
Mirrored egress packets are being sent to the mirror port even when the port is in the link
down state.
BlackDiamond 12800 Switch
PD4-736301853,
PD4-435982111
A BlackDiamond 12808 series switch may, in some cases, experience the wrong CLEAR-
Flow rule trigger and associated actions.
PD4-444211398 Hotswapping multiple I/O modules during an MSM soft reboot causes an I/O failure.
PD4-466153001,
PD4-488754250,
PD4-483661511
When configuring 20,000 learned IP Address Resolution Protocol (ARP) entries, only 8,000
IP hosts are sent.
PD4-421365551 When sending bidirectional L2 traffic between two ports, the FDB table shows the MAC
address as "unknown."
PD4-462788985 An MSM failover from MSM-A to MSM-B with multiple Ethernet Automatic Protection
Switching (EAPS) domains causes a continuous loop with Internet Group Management
Protocol (IGMP) traffic.
PD4-458894821 Sending bidirectional line rate traffic between two pairs of ports causes a drop in traffic rate.
PD4-413420051 Hot swapping multiple I/O modules at one time causes most of the I/O modules to be stuck
in a failed state.
PD4-463434121 Disabling and enabling a primary port multiple times causes traffic to continuously loop.
BlackDiamond 20808 Switch
PD4-528151231 A BlackDiamond 20808 switch crashes when configuring 10,000 IGMPv3 receivers and
5,000 streams and then running the disable ports all and enable ports all
commands.
PD4-679461441 When installing firmware using the install firmware command on a partially loaded
chassis the installation skips both fan tray upgrades and proceeds to upgrading the MMs.
Note: To ensure all fans are operational, run the show fans command before running the
install firmware command.
PD4-679154680 Booting up a BlackDiamond 20808 switch may take as long as 700 seconds in same
cases.
Table 49: Platform-Specific and Feature PDs (Continued)