Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.3.4 Release Notes
104
Resolved Issues in ExtremeXOS 12.3.1
The following issues were resolved in ExtremeXOS 12.3.1. The numbers shown in column one of the
following table are for internal reference and can be ignored. ExtremeXOS 12.3 includes all fixes up to
and including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.3, and
ExtremeXOS 12.2.2-patch1-6. For information on those fixes, see the release notes for the specific release.
QoS
PD4-807111909,
PD4-807111891
The QoS profile configuration command is not displayed in the output of the show
configuration vlan command for the learning-domain vMANs.
PD4-828265339,
PD4-805461986,
PD4-537092174
Enabling diffserv examination on Summit family or BlackDiamond 88000 series switches
causes dot1p replacement of 802.1q tagged packets.
ScreenPlay
PD4-817159826 The following message is periodically logged when the Event Log screen is left open in
ScreenPlay:
Login passed for user admin through xml (::)
STP
PD4-822468490,
PD4-538752306
The load script command displays an error if the script file contains Multiple Spanning
Tree Protocol (MSTP) configurations.
VRRP
PD4-767558378,
PD4-629585032
VRRP backup does not return the real IP address of the VRRP master for the SNMP object
vrrpOperMasterIpAddr.
Table 49: Platform-Specific and Feature PDs
PD Number Description
General
PD4-438482720 When a (*,G) entry is removed, the hold timer should be restarted for the next maximum
hold time.
PD3-207678214 The user-configured banner remains active when rebooting a switch without first saving the
configuration.
PD4-715297301 Uninstalling an SSH module causes a switch to fail.
PD4-549307711 The command output for the show fan command shows an incorrect FRU_Error.
PD4-730988500,
PD4-488646640
In some instances, vMAN configuration commands are displaying as VLAN configuration
commands in the output of the show configuration command. For example,
configure vman vman2 qosprofile QP3 displays as configure vlan vman2
qosprofile QP3.
PD4-730988476,
PD4-488295907
For BlackDiamond 8800 and Summit platforms, the ExtremeXOS CLI currently allows using
the same vMAN Ethertype for both the primary and the secondary Ethertypes.
PD4-735566061,
PD4-623659052
The extremeFdb MIB entry last-updated field is not updated after adding
extremeFdbMacExosFdbTable to the extremeFdb MIB.
Table 48: Platform-Specific and Feature PDs (Continued)
PD Number Description