Specifications

Page 39
©
2012 Sargent and Greenleaf
Revision date: 9/19/2012
SARGENT AND GREENLEAF
®
A Subsidiary of Stanley Security Solutions, Inc.
Dimensions— 6125, 6127, 6129 series CAse
Standard bolt extension:
Locked = 0.461 (11,71 mm)
Unlocked = 0 (flush with case)
Throw = 0.461 (11,71 mm)
Travel screw removed:
Locked = 0.461 (11,71 mm)
Unlocked = -0.08 (-2 mm) (recessed)
Throw = 0.54 (13,71 mm)
travel screw removed
standard
Specifications for the user-supplied switch needed to signal models 6125, 6127, and 6129 that safe boltwork is extended
and it is okay to extend the lock bolt:
Minimum voltage rating: 30 VDC
Minimum current rating: 50 milliamperes
Electrical contact material: silver
Switch operation: snap acting contacts
Contact configuration: lock bolt extends on contact closure
Switch actuator: recommend lever or roller actuator, depending on boltwork design
Switch operating life: minimum of 50,000 cycles
Switch connectors: recommend .110" (2.8 mm) X .020" (.5 mm) quick connect tabs
The bolt throw of the 6125, 6127, and 6129 can be adjusted. If
your application requires more than .46" (11,7 mm) bolt travel,
remove the bolt travel adjustment screw and add a .075" (2 mm)
thick spacer when attaching safe boltwork to the lock bolt.
BOLT TRAVEL SCREW
.281
7,1 mm
2.400 (61,0 mm)
1.165 (30 mm)
.312
7,9 mm
.59 (15 mm)
M4 –.7 holes
6125
6127
6129
1.624" (41,2 mm)
1.000 (25,4 mm)
2.624 (66,6 mm)
3.320 (84,3 mm)
Bolt extension:
Locked = .461
(11,71 mm)
Unlocked = .125
(3,18 mm)
6125
6127
6129