Specifications
23
HE1G-L Grip Style Three-position Enabling Switches
Specifications
Applicable Standards
UL508 (UL listed, screw terminal only)
CSA C22.2, No. 14 (c-UL listed, screw
terminal only)
IEC/EN 60947-5-1 (TÜV/BG approval)
GS-ET-22 (TÜV/BG approval)
Applicable Standards
for Use
ISO 12100-1, -2, IEC 60204-1/EN 60204-1,
ISO11161 / prEN11161, ISO 10218 / EN 775,
ANSI/RIA R15.06, ANSI B11.19
Operating
Temperature
Silicon rubber boot:
–25 to 60°C (no freezing)
NBR/PVC Polyblend rubber boot:
–10 to 60°C (no freezing)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree 3
Contact Resistance 100 mΩ maximum (initial value)
Insulation
Resistance
Between live and dead metal parts:
100 MΩ minimum (500V DC megger)
Between terminals of different pole:
100 MΩ minimum (500V DC megger)
Impulse Withstand
Voltage
Screw terminal:
2.5 kV (momentary pushbuttons: 1.5 kV)
Internal connector: 1.5 kV
Electric Shock
Protection Class
Class II (IEC 61140)
Operating Frequency 1,200 operations per hour
Mechanical
Durability
Position 1 → 2 → 1:
1,000,000 operations minimum
Position 1 → 2 → 3 → 1:
100,000 operations minimum
Electrical Durability
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC,
100 mA)
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 1,000 m/s
2
Vibration Resistance
Operating extremes:
5 to 55 Hz, amplitude 0.5 mm minimum
Damage limits:
16.7 Hz, amplitude 1.5 mm minimum
Applicable Wire
Screw terminal:
0.14 to 1.5 mm
2
(AWG16 to 25)
Internal connector:
0.05 to 0.86 mm
2
(AWG18 to 30)
Applicable Cable Outside diameter ø7 to 13 mm
Conduit Port Size
M20 (cable gland is supplied with the grip
style enabling switch)
Terminal Tensile
Strength
20N minimum
Terminal Screw
Tightening Torque
0.5 to 0.6 N·m
Degree of Protection
HE1G-L21SM: IP66 (IEC 60529)
HE1G-L20ME: IP65 (IEC 60529)
HE1G-L20MB: IP65 (IEC 60529)
HE1G-L21SMB: IP65 (IEC 60529)
Conditional Short-
circuit Current
50A (250V) (Use 250V/10A fast-blow fuse for
short circuit protection.)
Direct Opening
Force
70N minimum (monitor switch)
Operator Strength
500N minimum (when pressing the entire
button surface)
Weight (approx.)
HE1G-L21SMC: 190g
HE1G-L21SM/L21SMCB/L20MCB: 200g
HE1G-L21SMB/L20MB: 210g
HE1G-L20MCE: 230g
HE1G-L20ME: 240g
Operating Characteristics
HE1G-L21SM, HE1G-L21SMC,
HE1G-L21SM-1N, HE1G-L21SMC-1N
Terminal No.
Terminal Block/
Internal Connector
1–2 / A1-B1
5–6 / A3-B3
3–4 / A2-B2
Pressing
(Position 1→2→3)
1–2 / A1-B1
5–6 / A3-B3
3–4 / A2-B2
Releasing
(Position 2→1)
1–2 / A1-B1
: contact ON (closed) : contact OFF (open)
5–6 / A3-B3
3–4 / A2-B2
Releasing
(Position 3→1)
Position 1 Position 2 Position 3
Terminals 1-2/A1-B1 and 3-4/A2-B2 are outputs of the 3-position enabling •
switch.
Terminals 5-6/A3-B3 are outputs of the monitor switch.•
The above operation characteristics show when the center of the grip style •
enabling switch button is pressed. Because two contacts are designed
to operate independently, pressing the edge of the button turns on one
contact earlier than the other contact, causing a delay in operation. To
avoid this, always press the center of the button.
Dimensions
HE1G-L21SM, HE1G-L21SMC,
HE1G-L21SM-1N, HE1G-L21SMC-1N
174
(86)
5846
54
Cable Gland (supplied with grip style
enabling switch)
Part No.: SKINTOP BS-M20 × 1.5 (LAPP)
Internal Connector Terminal No.
A4A3A2A1
B4B3B2B1
Connector
Tyco Electronics D-1200D series
Receptacle housing: 1-1827864-4•
Receptacle contact•
1827586-2: AWG28 to 30
(Hand tool: 1762952-1)
1827587-2: AWG22 to 28
(Hand tool: 1762846-1)
1827588-2: AWG22 to 28
(Hand tool: 1762950-1)
1827589-2: AWG18 to 22
(Hand tool: 1762625-1)
Accessory
Mounting Bracket HE9Z-GH1 (for hanging the switch)
50
20
33
81
Material: SUS304
Thickness: 3.0 mm
(For M5 mounting screws)
2-øM.5
86
Plastic Coating
Note: Available for HE1G/HE1G-L/HE9Z-GSH51 only.