HE3B ø16mm Rectangular Three-position Enabling Switches
Rectangular operator part with ø16 mm mounting for easy installation.
2-contact 3-position enabling switches ideal for installing in small teach pendants.
Ergonomically-designed OFF-ON-OFF operation.
Easy recognition of position 1 to 2 transition is made possible by
a snap action switch.
Suffi cient difference in operating force is provided for shifting
from position 2 to position 3.
Low pressure is required to maintain in position 2 allowing for
longtime operation.
Reliable operation is assured even when the edge of the operator
button is pressed.
The switch does not turn ON while being released from position 3
(OFF) to position 1 (OFF) (IEC60204-1, 9.2.5.8).
Two contacts are provided in a 3-position enabling switch so that
even one contact fails due to welding or short-circuit, the other
contact can disable machine operation.
The waterproof rubber boot provides IP65 protection.
HE3B
Style
Contact
Confi guration
Part No. Ordering No.
Package
Quantity
Without Rubber Boot
2 contacts
(3-position
switch)
HE3B-M2
HE3B-M2 1
HE3B-M2PN10 10
With Rubber Boot
Rubber Boot Material:
Silicon Rubber
Color:
Y: yellow, B: black
HE3B-M2P
HE3B-M2P
1
HE3B-M2PPN10
10
Rubber Boot Material:
NBR/PVC Polyblend
Color: gray
HE3B-M2PN1
HE3B-M2PN1 1
HE3B-M2PN1PN10
10
Note: Specify a rubber boot color code in place of in the Ordering No.
Contact Ratings
Rated Insulation Voltage (Ui) 125V
Rated Thermal Current (Ith) 3A
Rated Voltage (Ue) 30V 125V
Rated
Current
(Ie)
AC
Resistive Load (AC-12) 1A
Inductive Load (AC-15) 0.7A
DC
Resistive Load (DC-12) 1A 0.2A
Inductive Load (DC-13) 0.7A 0.1A
Contact Confi guration (3-position switch) 2 contacts
Minimum applicable load (reference value): 5V AC/DC, 1 mA
(Applicable range is subject to the operating conditions and
load.)
Specifications
Applicable Standards
UL508 (UL recognized), CSA C22.2, No. 14 (c-UL recognized)
IEC/EN 60947-5-1, IEC/EN 60947-5-8 (TÜV approval)
Applicable Standards for Use
ISO 12100-1, -2, EN 12100-1, 2, IEC 60204-1 / EN 60204-1
ISO 11161 / prEN 11161, ISO 10218 / EN 775
ANSI/RIA R15.06, ANSI B11.19
Operating Temperature
–25 to +60°C (no freezing) (without rubber boot, with silicon rubber boot)
–10 to +60°C (no freezing) (with NBR/PVC polyblend rubber boot)
Relative Humidity 45 to 85% (no condensation)
Storage Temperature –40 to +80°C (no freezing)
Pollution Degree
2 (inside panel, terminal side)
3 (outside panel, operator side)
Contact Resistance 50 mΩ maximum (initial value)
Insulation Resistance
Between live and dead metal parts: 100 MΩ minimum (500V DC megger)
Between terminals of different poles: 100 MΩ minimum (500V DC megger)
Impulse Withstand Voltage 1.5 kV
Operating Frequency 1,200 operations per hour
Mechanical Durability
Position 1 2 1: 1,000,000 operations minimum
Position 1 2 3 1: 100,000 operations minimum
Electrical Durability 100,000 operations minimum
Shock Resistance
Operating extremes: 150 m/s
2
Damage limits: 500 m/s
2
Vibration Resistance
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits: 16.7 Hz, amplitude 1.5 mm
Terminal Style Solder terminal
Applicable Wire 1 cable, 0.5 mm
2
maximum
Terminal Soldering Heat Resistance 310 to 350°C, 3 seconds maximum
Terminal Tensile Strength 20N minimum
Locking Ring Recommended Tightening Torque 0.68 to 0.88 N·m
Degree of Protection
IP40 (without rubber boot)
IP65 (with rubber boot) (IEC 60529)
Conditional Short-circuit Current 50A (250V) (Use 250V/10A fast-blow fuse for short-circuit protection.)
Operator Strength 500N minimum (pressing the entire operator surface)
Weight (approx.)
14g (without rubber boot)
18g (with rubber boot)