User guide

158 DISPLAY CONTENT MANAGER — Installation and User Guide
Section 4 — Material Screen
Figure 194. Serial Command Edit Command Dialog
Enter the following information:
Command
The sequence of control characters that are issued to the device to cause
it to perform the desired action.
Note Consult the documentation for the designated device to learn what command
sequences, formats and terminators are accepted for control of the device.
Code type
Serial codes may be issued as ASCII or HEX characters
•Teminator
The special character (if any) that is needed to terminate a particular
command sequence
After entering the required information for the selected command, click the
OK button close the Edit command dialog.
Terminator
If you wish to change the terminator for the selected command, click in the
Terminator field and select a new terminator in the Edit command dialog
(see Figure 194).
Figure 195 shows a sample Serial Command Properties Window after all
data has been entered.