SDS
Gasmixture R410A
Safety Data Sheet    
    Version: 2.0 
01/03/2020  EN (English) 
Page 1 
SECTION 1: Identification 
1.1.  Identification 
Product form  :  Mixture 
Trade name  :  Gasmixture R410A 
Product code  :  R410A 
1.2.  Recommended use and restrictions on use 
No additional information available 
1.3.  Supplier 
Ruyuan Dongyangguang Fluorine Co.,Ltd. 
Chlor-Alkali Industry Base, Development Zone of Ruyuan County, GUANGDONG, CHINA 
512721 
T +86-(0)751-5286592 
zhanggh.ginny@dyg-hec.com 
1.4.  Emergency telephone number 
Emergency number  :  +86-(0)532-83889090 
SECTION 2: Hazard(s) identification 
2.1.  Classification of the substance or mixture 
GHS-US classification 
Gases under pressure : Liquefied gas  Contains gas under pressure; may explode if heated. 
2.2.  GHS Label elements, including precautionary statements 
GHS-US labelling 
Hazard pictograms (GHS-US)  : 
Signal word (GHS-US)  :  Warning 
Hazard statements (GHS-US)  :  Contains gas under pressure; may explode if heated. 
Precautionary statements (GHS-US)  :  Protect from sunlight. Store in a well-ventilated place. 
2.3.  Other hazards which do not result in classification 
Other hazards not contributing to the 
classification 
:  Asphyxiant in high concentrations. Contact with liquid may cause cold burns/frostbite. 
2.4.  Unknown acute toxicity (GHS US) 
Not applicable 
SECTION 3: Composition/information on ingredients 
3.1.  Substances 
Not applicable 
3.2.  Mixtures 
Name  Product identifier  %  GHS-US classification 
Difluoromethane (R32) 
(CAS-No.) 75-10-5  50 w/w  Flam. Gas 1, H220 
Press. Gas (Liq.), H280 
Pentafluoroethane 
(CAS-No.) 354-33-6  50 w/w  Press. Gas (Liq.), H280 
Full text of hazard classes and H-statements : see section 16 
SECTION 4: First-aid measures 
4.1.  Description of first aid measures 
First-aid measures after inhalation  : 
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep 
victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing 
stopped. 
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2020 / Rules and Regulations
Revision date: 01/03/2021Date of issue: 01/03/2021