Revision date: 6/23/2014
CLASS 2
B
6128 A-series
™
Order Number
6129 A-series
™
Order Number
Non-Tamper
Keypad
Keypad Extension
Bolt Position Indicator Reset Code
6128-240 6129-240 yes yes yes no
Lock Kits—lock, keypad, keypad extension, serial number plate
• Underwriters Laboratories Listed Type 1, VdS Class 2, CEN B, A2P B/E, and RoHS compliant.
• Up to sixteen users in Bank Mode—One programmer code, two officer codes, four administrator codes, and ten user codes.
• Dual Control and Manager/Employee modes selectable and changeable at any time by entering a special keypad command.
• 400-event, time and date stamped audit trail managed by easy-to-use PC-based software. To read audit trail information, you will need the optional
audit trail software kit (part #6103-120). Time, date, and event duration information is generated and stored in the lock so that it is not susceptible to time drift.
• Snap-in touch key reader allows fast, accurate transfer of audit trail data.
• Both models incorporate a penalty time feature to prevent opening by entering sequential or random codes until a valid code is found.
• Both models offer time delay of one to ninety-nine minutes.
• Both models offer a duress capability, allowing a distress signal to be sent through the customer’s central alarm system in the event of an
emergency. A duress module (part #6102-090) or alarm interface module (part #6102-025) is required to use this function.
• The 6128 A
-series
™
Lock is made for boltwork blocking applications that do not require direct attachment of the lock bolt to the safe’s boltwork.
• The 6129 A-series
™
Lock is designed for direct boltwork attachment and will push and pull 2.24 lbs. (10 newtons), with a maximum load of 5.6
lbs. (25 newtons).
• All models are equipped with a bolt position indicator that closes a circuit when the lock bolt is in either the locked or unlocked position.
• Both models can be opened via Dallas
®
iButton
®
keys in conjunction with one time codes (OTC) when service mode is enabled. Contact a
Sargent & Greenleaf sales representative (800 826-7652) for information about service mode and LMS software.
6128 and 6129 A-
series
™
ATM Locks
SG Audit Software runs on Windows
®
7, Windows
®
Server 2008, and Windows
®
Vista operating
systems. It includes a cable with a Dallas
®
key reader and a Dallas
®
iButton
®
for transferring the audit
information from the lock to your computer. Check your computer to see whether you will need the serial
adapter or USB adapter. The appropriate driver software is included with each type of adapter. The
keypad extension base and audit trail software kit are both needed to download, view, and manage time
and date-stamped audit information captured by a 6126, 6127, 6128, or 6129 lock.
USB ADAPTER/CABLE
SERIAL ADAPTER/CABLE
TYPE 1
A-seAl BOX
6103-130—Audit trail software on CD, serial adapter with cable, and Dallas
®
iButton
®
.
6103-131—Audit trail software on CD, USB adapter with cable, and Dallas
®
iButton
®
.
6103-102—Key reader with USB adapter with cable only.
6104-006—Extra Dallas
®
iButton
®
(red fob).
6102-025—Alarm interface module for 6126, 6127, 6128, and 6129.
6128-500—A-seAl box with 9-volt battery.
6102-302— Field Service App (FSA) license for remote A-series key reader and management
programming. Includes iButton key reader, USB adapter, and a MICRO-USB connector
for your Android device.
6102-303— Field Service App (FSA) license the same as the 6102-302 above, but includes the less common
MINI-USB adapter in place of of the MICRO adapter.