Datasheet

724-746-5500 blackbox.com
BL A C K B O X
®
3 of 3
09/13/2011
#10676
TeCh SPeCS
Compliance — FCC Part 15 Class A, DOC Class/MDC classe A
Interface — RS-232, full-duplex, asynchronous
Protocol — Asynchronous
Code Set — ASCII
Data Format — 7 or 8 data bits with even, odd, or no parity (user-selectable);
1 stop bit (fixed)
Flow Control — Hardware (DTR/CTS) or software (X-ON/X-OFF),
user-selectable
Operation — Full-duplex
Data Rate — 19,200, 9600, 4800, 2400, 1200, 600, 300, or 110 bps,
user-selectable
Maximum Distance — 50 ft. (15.2 m) to any attached device using standard
cables, or 500 ft. (152.4 m) using Extended Distance Data Cables
Internal Memory — 8 KB of buffer RAM
User Controls — ASCII characters from master device; (7) Internal 8-pos. DIP
switches: (2) for system options, (5 or 9*) for port options; (5 or 9*) Internal
jumpers for DTE/DCE; (1) Front-mounted reset button
*1 for each basic or expanded port
Diagnostics — Various self-tests
Indicators (10) Front-mounted LEDs: (1) Power, (1) Lockout, and (8) Link
Status
CE Approval — Yes
Connectors — (5 or 9*) Rear-mounted DB25 female
Leads Supported — Pins 1 through 8, 20, and 22
MTBF — 20,000 hours (16,000 hours with Expansion Board)
Temperature Tolerance — Operating: 32 to 113°F (0 to 45°C);
Storage: –4 to 158°F (–20 to 70°C)
Humidity Tolerance — 0 to 95% noncondensing
Enclosure — Steel
Power — Through nondetachable desktop power supply:
SW590A-R2: 115 VAC, 60 Hz; SW590AE-R2: 230 VAC, 50 Hz
Size — 2.3"H x 12.2"W x 11"D (5.8 x 31 x 27.9 cm)
Weight — Base unit with power supply: 9.6 lb. (4.4 kg);
Expansion board: 0.6 lb. (0.3 kg)
NOTE: Technical specification weight is the unit weight. It is not
the packaged shipping weight. For shipping weight, please contact
Black Box customer service at 877-877-2269.
Technically Speaking
The control sequence of the Code Operated Switch II is a pair
of ASCII characters: one “arming character” that gets the box’s
attention and prepares it to switch, and one “port-selection
character” that identifies the port to switch to. You can select
any of the 256 characters in the extended ASCII character set
to be the arming character.
Graphics data can include almost any combination of
characters, including those of the COS II’s control sequences.
For this reason, the COS II has agraphics pause” feature
that allows it to handle graphics files without unintentional
switching: A pause (an absence of data) whose length you
can set must occur before the COS II will recognize a pair of
characters as a control sequence; otherwise, the COS II will
pass the characters as data.
You can also choose whether the COS II passes the hardware
flow-control leads DTR and CTS through to the attached
devices, or uses them strictly to control its buffer.
You may also need:
A snap-in 4-Port Expansion Board for controlling four additional
slave devices. You can install this circuit board in only minutes
with just a screwdriver.
An asynchronous RS-232 modem or line driver
for long-distance control of your devices.
RS-232 cable.
AC and data-line surge protectors.
A country-specific power cord or adapter for operating
the COS II outside of North America.
Communications software.
Item Code
Code Operated Switch II
115 VAC
SW590A-R2
230 VAC
SW590AE-R2
You may also need…
4-Port Expansion Board
SW591C
Extended Distance Data Cable (12 conductors)
EDN12C
SM5090A-R2:
top: rear view;
bottom: front view