AIR CONDITIONER ASSEMBLY, MAINTENANCE AND USE INSTRUCTIONS Model Number: SW2000PLUS Serial Number:__________________
GENERAL WARNINGS When installing, be sure to carefully follow the instructions given in this manual. The manufacturer declines all responsibilities for damage to equipment or people caused by non-standard system installations or modifications. NOTES When indicated, the right side of the vehicle is the “passenger side” and the left side of the vehicle is the “drivers side”.
SLEEPING WELL ARCTIC PLUS 3
Qty Description EVAPORATOR CONNECTION KIT CONDENSER CONDENSER MOUNTING KIT COMPRESSOR BOX COMPRESSOR BOX MOUNTING KIT 1 1 1 1 1 1 TECHNICAL DATA Cooling Capacity: Up to 6100 BTU Power Consumption: Up to 62A (12V) Functioning with Engine Off: Voltage: 12V DC Refrigerant: R-134A 6 Ventilation Speeds Electronic temperature control with digital control panel Auto – low voltage Shutdown (Battery Saver) Evaporator Weight: 11.5 Lbs Condenser Weight: 15.9 Lbs Compressor Box Weight: 54.
Evaporator MUST be mounted as high as possible in the sleeper area. The unit cannot be mounted under the bunk. NOTE: Install return air vents if unit is enclosed in a cabinet.
ELECTRIC DIAGRAM COLOR B G H CODE WHITE YELLOW GRAY COLOR M N R CODE BROWN BLACK RED COLOR V X Y CODE GREEN WHITE/RED RED/BLACK 14
All 4 buttons must be pressed at the same time 16
OPERATION / CONTROL PANEL “SLEEPING WELL ARCTIC PLUS” CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY. CONDITIONING (AC) T0: TEMPERATURE SET BY USER Tamb: AMBIENT TEMPERATURE DETECTED BY PROBE V1: COMPRESSOR ROTATION SPEED (2500 Rpm) V2: COMPRESSOR ROTATION SPEED (4000 Rpm) ON/OFF When the system is OFF, press the ON/OFF button (see fig. 1) for more than one (1) second to turn the A/C system ON. The A/C system will start in STANDARD MODE (V1).
ERRORS SHOWN ON THE DISPLAY (AC / FAN) Description Battery Voltage (The battery-saver device has cut out. Voltage has fallen below the value of 10.8V D.C.) Fan Over Current Cut-Out (The condenser or evaporator fan overloads the central control unit above the limit allowed. Possible cause: short circuit or blockage of fan rotation.) Message Compressor Locked (The rotor is locked or the pressure inside the cooling circuit is too high.
REFRIGERANT FILLING PROCEDURE Before charging the system, (by means of the charge fittings on the condenser unit and compressor block) run vacuum cycle for 30 minutes. Disconnect the high-pressure attachment. Charge the system with 17.6oz (500 grams) R-134a into the circuit through the low-pressure attachment. Switch the Sleeping Well Arctic Plus on for 10 minutes before disconnecting the charging hose(s). When the refrigerating charge cycle is over, check for leaks and proper operation of the system.
Spring Summer Fall Winter Condenser Visual Inspection SYSTEM MAINTENANCE Compressor Box Evaporator Visual Inspection Visual Inspection Batteries (Accessory) Visual Inspection Visual Inspection Visual Inspection Visual Inspection Condenser - Visual Inspection - Visual Inspection Core should be clear/free of dirt and debris. Bracket mounting bolts are tight and secure to rear exterior sleeper wall. Freon High/Low connections are not damaged and are secure.
Service Parts Breakdown
Parts Breakdown Part Number SW112 SW114 SW146 SW152 SW153 SW156 SW159 SW166 – Use BT8-8606 SW167 – Use BT8-8608 SW168 SW169 SW175 SW176 SW212 SW226 SW227 SW228 SW229 SW230 SW231 SW232 SW233 SW234 SW235 SW236 SW237 SW238 SW239 SW240 SW241 SW242 SW243 SW244 SW245 SW246 SW247 SW248 SW249 SW250 SW251 SW252 SW253 – Use BT0-5027 SW254 – Use BT0-5023 SW255 – Use BT0-5000 SW256 – Use BT0-5001 SW257 – Use BT0-5024 Description Air Vent Comm Cable between Splitter and Condenser Unit Manostat Diffuser Plastic Cover Ev