Network Hardware User Manual
43
CHAPTER 5: Installation
2. To activate the battery, connect the pins for a two-pin group by placing the
jumper across both pins. For a three-pin group, connect jumper cap across
the two pins labeled ON.
NOTE
To disable the battery on the control card, for a two-pin jumper group
disconnect the jumper cap across both pins so they rest on only one
pin. For a three-pin jumper group, connect the jumper cap across two
pins labeled OFF.
Setting the Configuration DIP Switches (DS5)
The configuration DIP switches set the following:
• Enable/disable rack password
• Cold/warm RESET button configuration
• Enable/disable NORM SET and N gang switch buttons
• Communication baud rate
Tables 5-1 through 5-4 illustrate the DIP-switch settings.
DIP Switch Tables
Table 5-1. DIP Switches at DS7
Switch Position In order to… Notes
1 ON Enable the Ethernet port.
OFF Disable the Ethernet port.
2 OFF – Always set to OFF.
3 ON Enable the AUX port.
OFF Disable the AUX port.