AUGUST 2010 PFBS120 PFBS240 Power Fallback Switch CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.
POWER FALLBACK SWITCH - QUICK START GUIDE FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
POWER FALLBACK SWITCH - QUICK START GUIDE NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4.
POWER FALLBACK SWITCH - QUICK START GUIDE WARNINGS AND CAUTIONS Secure Racking If secure racked units are installed in a closed or multi-unit rack assembly, they may require further evaluation by certification agencies. Consider the following items: 1. The ambient temperature within the rack may be greater than the room ambient temperature. Installation should be such that the amount of airflow required for safe operation is not compromised.
POWER FALLBACK SWITCH - QUICK START GUIDE Specifications Physical/Environmental: Width: 17" (48.3 cm) (Including Rack Brackets) Depth: 8.7" (22.1 cm) Height: 1.75" (4.5 cm) One Rack U Operating Temperature: 32˚F to 122˚F (0˚C to 50˚C) Humidity: 10 - 90% RH Power Input Feeds: PFBS120: Two (2) IEC-60320-C14 Inlets. PFBS240: Two (2) IEC-60320-C20 Inlets. Power Outlets: PFBS120: Eight (8) each, NEMA 5-15R Outlets. PFBS240: Eight (8) each, IEC-60320-C13 Outlets.
POWER FALLBACK SWITCH - QUICK START GUIDE Quick Start Guide This Quick Start Guide describes the installation procedure for the Power Fallback Switch. The Power Fallback Switch automatically switches power from a primary input to a secondary input when power to the primary input is lost or interrupted.
POWER FALLBACK SWITCH - QUICK START GUIDE 7
© Copyright 2010. Black Box Corporation. All rights reserved.