The ME670A has two sets of eight switches, yielding 16 total DIP switches. The two
sets will be referred to as SW1 and SW2. As
Figure 2 shows, the orientation of all DIP
switches is the same with respect to “ON” and “OFF” positions.
Figure 2. Close up of cofiguration switches
2.3 SWITCH SET SW1
The DIP switches on SW1 set data rate, clock source, async./sync. mode and carrier
control method. The default settings are summarized in the table below.
SW1 through SW-4: Data Rate Setting
Switches SW1-1 through SW1-4 are set in combination to determine the asynchro-
nous and synchronous data rate for the ME670A.
Table 2. SW1 Summary Table
Position Function Factory Default
SW1-1 Data Rate On
9,600 bps
SW1-2 Data Rate Off
SW1-3 Data Rate Off
SW1-4 Data Rate On
SW1-5 Clock Source On
Internal
SW1-6 Clock Source On
SW1-7 Async./Sync. On Async,
SW1-8 Carrier Control Off Constantly On
Table 3: Data Rate Setting
SW1-1 SW1-2 SW1-3 SW1-4
Setting
(Kbps)
On On On On 1.2
Off On On On 1.8
ON
OFF
OFF
12345678