Installation manual

1-1
1. MOUNTING
1.1 Mounting Considerations
When selecting a mounting location for TZTBB, keep the following in mind:
The temperature at the mounting location shall be between -15°C and +55°C (wire-
less LAN: 0°C and +55°C).
The humidity at the mounting location shall be 93% or less at 40°C.
Locate the unit away from exhaust pipes and ventilators.
The mounting location should be well ventilated.
Mount the unit where shock and vibration are minimal (comply with IEC 60945
Ed.4).
Keep the unit away from electromagnetic field generating equipment such as mo-
tors and generators.
For maintenance and checking purposes, leave sufficient space around the unit and
leave slack in cables. Minimum recommended space is shown in the outline draw-
ings.
A magnetic compass will be affected if the equipment is placed too close to it. Ob-
serve the compass safe distances shown in the SAFETY INSTRUCTIONS to pre-
vent disturbance to the magnetic compass.
1.2 Processor Unit
The processor unit MPU-002 can be mounted on the tabletop or a bulkhead. Refer to
the outline drawing for mounting dimensions. For bulkhead mounting, be sure the unit
bottom is oriented downward.
Tabletop/ bulkhead mount
1. Decide the munting location for the unit.
2. Make four pilot holes for self-tapping screws in the mounting location.
3. Screw the self-tapping screws (φ6x20, 4 pcs.) into the pilot holes, leaving a clear-
ance of 5 mm.
4. Hang the unit on the screws.
5. Fasten all screws.