Specifications
724-746-5500 | blackbox.com
Page 8
Chapter 3: Mounting the Enclosure
3.2 Flat Surface Mount
When mounting the enclosure to a flat surface, the only other accessory that you need is the mounting plate. To ground the
SmartPath AP (LWN602HA), you must run a grounding wire from the lug nut on the underside of the enclosure to a grounded
object in the building.
1. Attach the mounting plate to a flat surface that can support its weight—approximately 15 pounds (6.8 kg)—and, optionally,
remove the wire from the grounding stud on the mounting plate (it will not be used). Then attach the enclosure to the
mounting plate (see Figure 7).
Using up to five #10 wood screws (not included)
with a minimum length of 1 1/2” (3.8 cm), attach
the mounting plate to a flat surface.
1a
Attach the enclosure to the mounting plate as
explained in the “Pole Mount” section.
1c
Mounting
Plate
(Remove the
grounding wire.)
SmartPath AP Enclosure
1b
Figure 7. Illustration of the SmartPath AP (LWN602HA) enclosure mounted to a flat surface.
2. Run a grounding wire from the lug nut at the bottom of the enclosure to a grounded object.