Specifications
724-746-5500 | blackbox.com
Page 2
Chapter 1: Contents (continued) and Chapter 2: Safety Instructions and Warnings
• (4) dual-band antennas for (1) AP
• (1) 12" (30.5 cm) unshielded CAT5 Ethernet cable
• (1) 30-watt power supply
• (4) RP-SMA antenna cables
NOTE: The SmartPath AP (LWN602HA) is not included with the SmartPath 602HA Outdoor Kit (LWN602A-OUT). For more
information, contact Black Box Technical Support at 724-746-5500 or info@blackbox.com.
You will also need the following tools:
• Screwdriver for
1
⁄4" (6-mm) slotted screws
• Screwdriver for cross-slotted 6-32 machine screws and #6 wood screws (Phillips #2 screwdriver)
• Drive sockets (nut drivers) for
1
⁄2" (13 mm),
3
⁄8" (10 mm), and
5
⁄16" (8 mm) nuts
•
5
⁄16" (8 mm) open-end wrench for coaxial antenna cable connectors
• Adjustable open-end wrench for cable grips
• (1) shielded CAT5 Ethernet cable rated for outdoor use; length determined by site requirements, but not to exceed 140 feet
(42.67 m)
2. Safety Instructions and Site Hazard Warnings
Read and follow these safety instructions and hazard warnings before installing a SmartPath AP (LWN602HA) outdoors. Also,
keep these instructions for future reference.
• To install the SmartPath AP (LWN602HA), you must be a qualified installation professional, licensed or certified in accordance
with local regulations.
• Make sure that the SmartPath AP (LWN602HA) enclosure and Ethernet protection device are connected to a suitably installed
ground conductor. Contact the appropriate electrical inspection authority if you are uncertain that suitable grounding is
available.
• To comply with RF (radio frequency) exposure limits, do not place the SmartPath AP (LWN602HA) within 8" (20 cm) of people.
• Do not locate the SmartPath AP (LWN602HA) enclosure near overhead power lines or other electric light or power circuits, or
where it can come into contact with such circuits. During installation, exercise extreme care not to come into contact with these
circuits, which can cause serious injury or death. For proper installation and grounding of the product, refer to national and local
electrical codes: NFPA (National Fire Protection Association) 70, National Electrical Code Article 810 (U.S.); Canadian Electrical
Code, Part I, CSA 22.1 and Section 54 (Canada). If local or national electrical codes are not available, refer to IEC (International
Electrotechnical Commission) 364, Part 1 through 7 (other countries).
• Do not connect or disconnect antennas or cables from the SmartPath AP (LWN602HA) during periods of lightning activity.
• You can install the SmartPath AP (LWN602HA) enclosure in wet, windy locations. Therefore, make sure to install closure caps
and securely fasten and waterproof all cable connections.
• Use only attachments and accessories specified by Black Box.
• After operating the SmartPath AP (LWN602HA), its rear surface can become hot. Use caution when handling it.