Chapter 5: Enclosing the SmartPath AP (LWN602HA)
5. Enclosing the SmartPath AP (LWN602HA)
With the shielded Ethernet cable and power line connected to the Ethernet protection device, you can now attach the SmartPath
AP (LWN602HA) to the internal mounting plate inside the enclosure. After that, connect the four antenna cables from the top of
the enclosure to the antenna connectors on the SmartPath AP, run the short Ethernet cable from the Ethernet protection device
to the SmartPath AP (LWN602HA) ETH0 port, and then connect the second power line to the SmartPath AP.
NOTE: Attach RP SMA terminators to the two middle antenna connectors labeled “B.” They will not be used.
1. Align the four slots on the rear of the SmartPath AP (LWN602HA) with the four tabs on the mounting plate. Then press the
SmartPath AP against the plate and downward, until the tabs slide inside the slots locking the SmartPath AP in place as shown
in Figure 10.
Position the SmartPath AP
so the four tabs go into the
slots.
Press the SmartPath AP
downward, letting its weight
secure the tabs in the slots.
(view from inside the SmartPath AP)
(The slots are on the other
side of the SmartPath AP.)
Slot on
SmartPath AP
Tab on internal
mounting plate
Figure 10. Attaching the SmartPath AP (LWN602HA) to the internal mounting plate.