3.3 Installing the 3-Slot Desktop Chassis
Install the chassis first before installing any modules into a 3-Slot Desktop
Chassis.
When installing the chassis, be sure to observe the following precautions to
prevent electrical or mechanical damage:
1. Stay within the chassis’ power rating to prevent overload of supply circuits or
damage to any overcurrent protection and supply wiring.
2. Maintain reliable ground, especially when connecting to a power strip instead
of directly to a branch circuit.
3. Protect the chassis from exposure to sunlight and electrical or magnetic
fields.
4. Make sure that the equipment rack remains stable, even with the addition of
the chassis and its associated cabling.
Use the 3-Slot Desktop Chassis. as a table-top chassis, mount in a Rackmount
shelf, or mount it to a wall surface.
1. Install the 3-Slot Desktop Chassis by placing it on a flat surface.
2. Make sure to leave adequate space on the sides of the unit to accommodate
cooling.
3. If mounting on a Rackmount shelf, align holes of the chassis to the shelf and
secure with screws.
Rackmounting requires a Rackmount shelf for mounting up to two units side by
side. The Rackmount shelf is sold separately. To purchase the Rackmount shelf
(part number (LMC5238); visit the Black Box Product Accessories page:
http://www.blackbox.com/Store/Results.aspx/search-LMC5238%5e%5e%5e/p-0
4. Attach the cables between the chassis and the device that will be
interconnected, and then plug the unit into a reliable, filtered power source.
5. If mounting the chassis on a wall, place two #10 panhead screws (not
supplied) on the wall according to the distance of the holes on the chassis,
and then hang the unit on the screws.
6. All versions are intended for use in a Restricted Access Location (RAL).
7. A readily accessible disconnect device shall be incorporated in the building
installation wiring.
8. A suitable listed circuit breaker shall be provided in the building installation as
the unit’s disconnect device. The branch circuit rating should be 15A, and
should be listed on the circuit breaker.