Datasheet
724-746-5500 blackbox.com
BL A C K B O X
®
5 of 8
05/18/2010
#10841
What is NEBS Level 3?
Network Equipment Building System (NEBS) standards
set requirements for telco equipment. The standards are main-
tained by Telcordia Technologies, Inc., formerly Bellcore. Bellcore
Special Report, SR-3580 defines three distinct functional levels of
NEBS compliance. The third of these levels, NEBS Level 3, is the
most stringent, certifying carrier-class equipment intended for
long-term use in variable environments.
NEBS Level 3 certifies that a piece of equipment can be safely
used in an extreme environment. To become certified at NEBS
Level 3, a device must meet strict physical, electrical, and environ-
mental requirements to prove it will operate safely and reliably
in extreme conditions. It must pass a series of tests that include
extreme heat, humidity, fire, earthquakes (Zone 4), light, and
noise.
Technically Speaking
Tech SpecS for chaSSiS
Power — LMC3004A–LMC3005A, LMC3010A, LMC3080A,
LMC3014A: 110–230 VAC, 50–60 Hz, autosensing, internal;
LMC3007A–LMC3008A, LMC3012A, LMC3081A: ± 48 VDC, internal;
LMC3015A: 110 VAC, 60 Hz, external (220-VAC power supply
available on request)
Size — 19-Slot Chassis: 3.5"H (2U) x 17.2"W x 14"D (8.9 x 43.7 x 35.6 cm);
5-Slot Chassis: 1.75"H (1U) x 17.2"W x 9"D (4.4 x 43.7 x 22.9 cm);
2-Slot Chassis: 1.9"H x 6.7"W x 5.5"D (4.8 x 17 x 14 cm);
1-Slot Chassis: 1"H x 3.8"W x 5.5"D (2.5 x 9.7 x 14 cm)
Weight —
19-Slot Chassis: Single power supply: 16 lb. (7.3 kg);
Dual power supplies: 18.5 lb. (8.4 kg);
5-Slot Chassis: Single power supply: 7.5 lb. (3.4 kg);
Dual power supplies: 9 lb. (4.1 kg);
2-Slot Chassis: 2.5 lb. (1.1 kg);
1-Slot Chassis: 1.5 lb. (0.7 kg)
Tech SpecS for ModuleS
Connectors — LMC3000A: (1) DB9 serial, (2) RJ-45 Ethernet,
(2) proprietary multichassis management ports;
Converter Modules: See ordering information on pages 6 –7
Indicators — LEDs:
LMC3000A: (1) Power, (3) Power Supply, (1) UTP Link, (1) Master,
(1) Slave, (1) Management Poll;
LMC3018C-R2–LMC3022C-R2: (1) Power, (1) Fiber Link, (1) UTP Link;
LMC3023C–LMC3032C: (1) Power, (1) Fiber Link, (1) UTP Link, (1) Auto,
(1) Half-/Full-Duplex;
LMC3033C–LMC3042C, LMC3084C–LMC3095C: (1) Power, (1) Fiber Link,
(1) UTP Link, (1) Auto, (1) UTP Half-/Full-Duplex, (1) Fiber Half-/Full-
Duplex, (1) 10/100;
LMC3051C–LMC3052C, LMC3054C–LMC3057C: (1) Power, (1) Fiber Link,
(1) UTP Link, (1) Fiber Half-/Full-Duplex;
LMC3058C–LMC3063C: (1) Power, (1) Fiber Optic Link, (1) Auto,
(1) Fiber, (1) Half-/Full-Duplex, (1) 10/100/1000;
LMC3064C–LMC3073C: (1) Power, (2) Fiber Optic Link;
LMC3044C–LMC3049C: (1) Power, (1) Fiber Optic Link, (1) UTP Link,
(1) Select, (1) Auto, (1) Half-/Full-Duplex;
LMC3043C: (1) Power, (1) UTP Link, (2) 10/100;
LMC3050C: (1) Power, (4) UTP Link, (4) 10/100;
LMC3074C–LMC3075C: (1) Power, (2) Fiber Optic Link;
LMC3076C–LMC3079C: (1) Power, (1) Test, (1) RJ-45/RJ-48 Link,
(1) Fiber Optic Link;
LMC3083C: (1) Power, (1) RJ-45 Link, (1) BNC Link;
LMC3100C–LMC3107C: (1) Power, (3) Power Supply, (1) Fiber Optic Link
(FO), (1) Master/Slave (BP), (1) 10 UTP, (1) 100 UTP, (1) FDX
Power — From the interface
Size — 2.8"H x 0.9"W x 4.5"D (7.1 x 2.3 x 11.4 cm)
Weight — 0.5 lb. (0.2 kg)
T e c h S p e c S f o r M a n a g e d d e S k T o p
and WallMounT ModelS
Connectors — See ordering information on page 8
Indicators — (1) Power, (3) Power Supply, (1) Fiber Optic Link (FO),
(1) Master/Slave (BP), (1) 10 UTP, (1) 100 UTP, (1) FDX
Power — LMC3100A–LMC3115A: 110 VAC, 60 Hz, external;
LMC3100AE – LMC3115AE: 220 VAC, 50 Hz, external;
LMC3100A-DC–LMC3115A-DC: 8–16 VDC
Size — 1"H x 3.8"W x 5.5"D (2.5 x 9.7 x 14 cm)
Weight — 1.5 lb. (0.7 kg)