Specifications

13
CHAPTER 2: Introduction
2.1.5 R
ECEIVER
The receiver contains several circuits (shown in Figure 2-1 below):
The RECEIVE FILTER removes all the out-of-band frequencies.
The AUTOMATIC EQUALIZER is made up of several equalizers activated
according to data rate.
The digital AGC (automatic gain control) automatically compensates for
the attenuation of the line. You can choose between the two modes of AGC
operations by setting the AGC jumper:
ON: The AGC operates continuously.
CNTR: The AGC is active only when DCD is ON. When DCD is OFF,
the AGC will remain in the state to which it was most recently set.
In full-duplex point-to-point applications, there is no difference between the
two AGC modes of operation.
Figure 2-1. Block diagram for the LDM-MR19.2.