User manual
LAN Connections
50 —
revision 3
10.1.3 Configuring the ETHLAN
Any additional changes specific to the hardware that the Lantronix box is connecting to should be made
now. These may include, but are not limited to, baud rate, parity, stop bit, byte size, and flow control.
1. Make sure the device is powered, completely booted, and connected to the network. Start
HyperTerminal.
2. Connect to the device using the IP address, port 7000 (terminal type VT100). Example:
3. A HyperTerminal session starts. Type:
access and press <Enter>. The access command will not echo.)
4. You will be prompted for a user name. Enter any name. There should be a command prompt.
5. Type:
set privileged and press <Enter>.
6. The password prompt will appear. The password is system.
7. For parity, type:
change parity [PARITY] <Enter>, where [PARITY] = none, even, odd, mark, or space.
8. For stop bits, type:
change stopbits [BITS] <Enter>, where [BITS] = 0, 1, or 2.
9. For byte size, type:
change charsize [SIZE] <Enter>, where [SIZE] = 7 or 8.
10. For flow control, type:
change flow control [FLOW CONTROL] <Enter>, where [FLOW CONTROL] = xonoff, ctsrts,
slowcts, or none.
11. For baud rate, type:
change speed [SPEED] <Enter>, where [SPEED] = the baud rate (9600, 2400, etc.)